Plan Review Notes
Plan Review Notes For Permit 06070451
Permit Number 06070451
Review Stop B
Sequence Number 1
Notes
Date Text
2006-08-15 00:00:00BUILDING PLAN REVIEW
 PERMIT: 06070445
 ADD: 2015 OKEECHOBEE BLVD.
 CONT: BOCA DEVEL. & CONST.
 TEL: (561)391-6227
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 EX FBC CODE= 2004 EXISTING FLORIDA
 BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS
 NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 3) ARCHITECT STEVEN L. COHEN AR0006819
 IS WORKING WITH A DELINGUENT LICENSE,
 EXPIRED 02/28/05.
 WWW.MYFLORIDA.COM/LICENSING
  
 4) THE ARCHITECTURAL AS WELL AS THE MEP
 PLANS ARE NOT SIGNED NOR SEALED.
 PLANS, SPECIFICATIONS, REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND
 BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 5) EX FBC 708.1 MINIMUM REQUIREMENTS.
 ALTERATIONS SUBJECT TOTHIS CHAPTER SHALL
 COMPLY WITH THE REQUIREMENTS OF CHAPTER
 13 OF THE FBC, BUILDING.
  
 6) EX FBC 706.1 A BUILDING, FACILITY OR
 ELEMENT THAT IS ALTERED SHALL COMPLY
 WITH CHAPTER 11 OF THE FBC BUILDING.
 SHEET A2 DOOR5/106 & 6/107 DO NOT MEET
 THE REQUIREMENTS OF 11-4.13.6
 MANEUVERING CLEARENCES AT DOORS. MINIMUM MANEUVERING
 CLEARANCES AT DOORS THAT ARE
 NOT AUTOMATIC OR POWER-ASSISTED SHALL BE
 AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITH
 IN THE REQUIRED CLEARANCES SHALL BE
 CLEAR & LEVEL.
  
 7) PROVIDE ADDITIONAL INFORMATION FOR
 A) SECURITY GRILLE LOCATED AT VESTIBULE
 B) VESTIBULE AUTO SLIDING DOORS
 LOCATED ON SHEET A2 & A5
 106.1.2* ADDITIONAL INFO.
  
 8) SHEET A7 DETAIL# 16 FLOOR SLAB,
 PROIDE INFORMATION ON TERMITE TRATMENT.
 1816.1 TERMITE PROTECTION.
 TERMITE PROTECTION SHALL BE PROVIDED BY
 REGISTERED TERMITICIDES, INCLUDING SOIL
 APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES
 APPLIED TO WOOD, OR OTHER
 APPROVED METHODS OF TERMITE PROTECTION
 LABELED FOR USE AS A PREVENTATIVE
 TREATMENT TO NEW CONSTRUCTION. SEE
 SECTION 202 , REGISTERED TERMITICIDE.
 UPON COMPLETION OF THE APPLICATION OF
 THE TERMITE PROTECTIVE TREATMENT, A
 CERTIFICATE OF COMPLIANCE SHALL BE
 ISSUED TO THE BUILDING DEPARTMENT BY THE
 LICENSED PEST CONTROL COMPANY THAT
 CONTAINS THE FOLLOWING STATEMENT: ?THE
 BUILDING HAS RECEIVED A COMPLETE
 TREATMENT FOR THE PREVENTION OF
 SUBTERRANEAN TERMITES. TREATMENT IS IN
 ACCORDANCE WITH RULES AND LAWS
 ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE
 AND CONSUMER SERVICES.?
  
 9) SHEET A-3 NOTES 3-5 INDICATE THAT
 PLYWOOD TO BE APPLIED TO WALL ROOM
 FINISH NOTES. IS THIS A WALL FINISH OR
 INCASED IN THE WALL?
 603.1 ALLOWABLE MATERIALS.
 COMBUSTIBLE MATERIALS SHALL BE PERMITTED
 IN BUILDINGS OF TYPE I OR II
 CONSTRUCTION IN THE FOLLOWING
 APPLICATIONS AND IN ACCORDANCE WITH
 SECTIONS 603.1.1 THROUGH 603.1.3 :
 1.FIRE-RETARDANT-TREATED WOOD SHALL
 BE PERMITTED IN:
 1.1.NONBEARING PARTITIONS WHERE THE
 REQUIRED FIRE-RESISTANCE RATING IS 2
 HOURS OR LESS.
 1.2.NONBEARING EXTERIOR WALLS WHERE
 NO FIRE RATING IS REQUIRED.
 TABLE 803.5 MERCANTILE OCCUPANCY
 SPRINKLERED FLAME SPREAD INDEX 76-200
 SMOKE DEVELOPMENT 0-450. IF THE PLYWOOD
 IS TO BE A FINISHED WALL THEN PROVIDE
 THE FLAME SPREAD AND SMOKE DEVELOPMEENT.
  
 10) A7 RESTROOMS SHOW COMPLIANCE WITH
 RESTROOM NONABSORBENT WALLS.PROVIDE
 MANUFACTURER INFORMATION.1210.2 WALLS.
 WALLS WITHIN 2 FEET (610 MM) OF URINALS
 AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT
 OF 4 FEET (1219 MM) ABOVE THE FLOOR, AND
 EXCEPT FOR STRUCTURAL ELEMENTS, THE
 MATERIALS USED IN SUCH WALLS SHALL BE OF
 A TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026