 1) FLOOR PLAN SHALL SHOW BEDROOM LAYOUT
 AND WHERE THE 2 DIFFERENT WINDOWS ARE TO
 BE INSTALLED. BE AWARE THAT THE EGRESS
 SWING OPEN WINDOWS FROM BOTH NOA'S HAVE
 A MAXIMUM SIZE LIMITATION OF 37"X50 5/8"
 IF YOU PLAN TO PUT 2 TOGETHER IN THE 75"
 OPENING A MULLION WOULD BE NECESSARY AND
 A PRODUCT APPROVAL WILL BE REQUIRED.
  
 2) PROVIDE ENGINEERED DESIGN FOR INFILL
 ESPECIALLY WHERE THE NEW WINDOW WILL BE
 ATTACHED, ALSO DETAIL THE NEW BUCK
 ATTACHMENT THAT SHALL BE DESIGNED TO
 TRANSFER THE WIND LOADS PLACED ON THE
 WINDOW TO THE STRUCTURE PER 1714.5.4.2
 FBC
  