| 2006-07-08 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2004 | | | | | | 1.)DESIGN PRESSURES FOR THIS JOB ARE | | | NOT CLEAR.YOU HAVE CIRCLED -47.2 ON | | | FBC TABLE 1609.6B.THE COMPUTERIZED | | | SHEET HAS PRESSURES RANGING FROM -38.1 | | | TO -42.5.SHEET 2 OF 11 OF THE PRODUCT | | | APPROVAL HAS -40 CIRCLED.UNTIL DESIGN | | | PRESSURES FOR THIS JOB ARE DETERMINED, A | | | COMPLETE REVIEW CANNOT BE DONE. | | | | | | 2.)YOUR ANCHOR SCHEDULE HAS A SPACING | | | OF 12".SEE SHEET 3 OF 11 OF YOUR | | | PRODUCT APPROVAL.ES55 REQUIRES 6" OR | | | 3". | | | | | | 3.)IT APPEARS THAT STORM BARS ARE | | | REQUIRED, BUT YOUR ANCHOR SCHEDULE | | | STATES "NO" IN THE STORM BAR COLUMN. | | | | | | 4.)SEE THE ATTACHED SAMPLE ANCHOR | | | SCHEDULE.YOU MAY PROVIDE THIS | | | INFORMATION IN ANOTHER FORMAT, BUT ALL | | | INFORMATION IS REQUIRED.FOR INSTANCE, | | | SUBTRATE INFORMATION WAS NOT PROVIDED. |
|