| 2006-12-07 14:49:25 | BUILDING PLAN REVIEW |
| | PERMIT: 06070002 |
| | ADD: 1601 FORUM PLACE |
| | CONT: PASS INTERNATIONAL |
| | TEL: (954)496-3133 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 3RDREVIEW |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) COMMENTS 3 & 4 REFER BACK TO THEA-1 |
| | SHEET DEALING WITH THE CEILING DETAIL. THE |
| | PLANS NOW INDICATE THE USE OF EFIS SYSTEM |
| | WITH 5/8" DENSEGLASS GOLD. |
| | |
| | |
| | 2A)THE REPORT SUBMITTTED ICC ES LEGACY REPORT 9838B |
| | HOLCIM ONE COAT STUCCO REPORT, |
| | THIS REPORT HAS THREE SUBSYSTEMS : |
| | SYSTEM NO. 1 USES 1/2 GYPSUM SHEATHING AND IS GOOD FOR |
| | 40 PSF |
| | |
| | SYSTEM NO. 2 USES 1/2" PLYWOODA COMBUSTIBLE, NOT |
| | ALLOWED IN HIGH RISE USE. |
| | |
| | SYSTEM NO. 3 USESS 1/2" OSB SHEATHING AS A BACKER |
| | BOARD, A COMBUSTIBLE ALSO NOT ALLOWES IN HIGH RISE |
| | USE. |
| | |
| | PROVIDE 2 SETS OF STO EFIS PRODUCT APPROVALS. |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 2B)THE SUBMITTED PRODUCT APPROVALS NOT REVIEWED BY |
| | THE DESIGNER OF RECORD. |
| | W P B ADMINISTRTIVE CODE 106.3.3* |
| | PRODUCT APPROVALS. THOSE PRODUCTS WHICH |
| | ARE REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL. |
| | |
| | 3) THIS IS A HIGH-RISE BUILDING PLEASE PROVIDE |
| | THE POSITIVE AND NEGATIVE PRESSURES THAT WILL BE |
| | ENCOUNTERED FOR BOTH THE INTERIOR ZONES AND END ZONES . |
| | THE DEIGNER OF RECORD SHALL REVIEW THE PRODUCTS TO SEE |
| | IF THEY WILL MEET THE PRESSURES. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | |