| 2006-10-04 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 06061717 |
| | ADD: 1001 OKEECHOBEE BLVD |
| | CONT: CHA TECH SERVICES, LLC |
| | TEL: (770)286-7297 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2ND REVIEW |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) FL S S 713.13 |
| | NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT BEFORE A |
| | PERMIT WILL BE ISSUED. NOTE: 713.13(2) |
| | IF THE WORK DESCRIBED IN THE NOTICE OF |
| | COMMENCEMENT IS NOT ACTUALLY COMMENCED |
| | WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. |
| | |
| | 3) COMMENT# 7 FROM THE PREVIOUS REVIEW |
| | DEALS WITH THE CONDUITS IN THE |
| | STAIRWELL, THAT ARE ENCASED IN A 2 |
| | LAYERS OF ROCK, 1" FIRECORE C CORE PANEL |
| | AND 1/2" DRYWALL. PLEASE PROVIDE THE |
| | LISTING FOR A 2 HR ASSEMBLY. 703.2 |
| | FIRE-RESISTANCE RATINGS. |
| | |
| | THE SECOND ISSUE IS THE LOCATION OF |
| | THIS ASSEMBLY IN THE STAIRWELL. 1009.4 |
| | STAIRWAY LANDINGS. THERE SHALL BE A |
| | FLOOR OR LANDING AT THE TOP AND BOTTOM |
| | OF EACH STAIRWAY. THE WIDTH OF LANDINGS |
| | SHALL NOT BE LESS THAN THE WIDTH OF |
| | STAIRWAYS THEY SERVE. EVERY LANDING |
| | SHALL HAVE A MINIMUM DIMENSION MEASURED |
| | IN THE DIRECTION OF TRAVEL EQUAL TO THE |
| | WIDTH OF THE STAIRWAY. SUCH DIMENSION |
| | NEED NOT EXCEED 48 INCHES (1219 MM) |
| | WHERE THE STAIRWAY HAS A STRAIGHT RUN. |
| | E07 INDICATES THAT THE SHAFT |
| | ENCLOSURE WILL BE 8" AWAY FROM THE WALL |
| | BUT THE LENGTH IN NOTE# 1 IS AS NEEDED. |
| | THIS COULD BE ACROSS THE WHOLE LANDING. |
| | 1009.4 STATES THE WIDTH OF LANDINGS |
| | SHALL NOT BE LESS THAN THE WIDTH OF THE |
| | STAIRWAYS THEY SERVE. |
| | |
| | THE THIRD ISSUE IS LOCATED ON E01 NOTE |
| | NUMBER 24, JUNCTION BOX SIZE AS REQUIRED |
| | BY THE NEC. THE ELECTRICAL PLAN REVIEWER |
| | |
| | MAY COMMENT ON THIS ISSUE. THERE CAN BE |
| | NO JUNCTION BOXES THAT WILL COMMUNICATE |
| | WITHIN THE STAIR TOWER. SEE ORIGINAL |
| | COMMENT 1019.2 PENETRATIONS INTO AND |
| | OPENINGS THROUGH AN EXIT ENCLOSURE. |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |