Plan Review Notes
Plan Review Notes For Permit 06061623
Permit Number 06061623
Review Stop P
Sequence Number 4
Notes
Date Text
2007-04-02 07:37:32DENIED;
 1.REVISED DRAWINGS ARE NOT DRAWN BY THE DESIGN
 PROFESSIONALS ON RECORD.
 2.PAGE A3.09 KITCHENETTE ; CABINET TO BE OPEN UNDER THE
 SINK FOR KNEE SPACE SEEFBC-2004 BUILDING SECTION
 11-4.24.3.
 3.SUBMIT SANITARY AND WATER RISER DIAGRAMS.
 4.LIST PLUMBING FIXTURES, SHOW MANUFACTURE OF 2
 COMPARTMENT SINK AND FLOOR SINK.
 5.PAGE P3.01, KEY NOTES; NOTE 1 CALLS FOR HOT WATER, NO
 WATER HEATER SHOWN ON PLANS AND NO ELECTICAL SHOWN ON
 PANEL RISER DIAGRAM.
 NOTE 53" CONDENSATE DRAIN TO RUN DOWN
 STREAM OF THE BATHROOM GROUP, SEE FBC-2004 SECTION
 909.1.NOTE 6, TRAP TO BE 1 1/2" FOR SINK.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695