| Plan Review Notes For Permit 06061539 |
| Permit Number |
06061539 |
|
| Review Stop |
P |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2007-04-19 08:31:51 | ****************PROVISO**************** | | | A} BEDROOM #3 BATH TUB SHOULD BE A SHOWER PER SHEET | | | A-2 FLOOR PLAN. | | | B} PER FBC-2004 PLUMBING, SECTION 708.3.5 A TWO-WAY | | | CLEANOUT IS REQUIRED AT THE JUNCTION OF THE BUILDING | | | DRAIN AND BUILDING SEWER. | | | C} PER FBC-2004 PLUMBING, SECTION 802.1.6 DOMESTIC | | | DISHWASHING MACHINES SHALL DISCHARGE INTO A WYE-BRANCH | | | FITTING ON THE TAILPIECE OF THE KITCHEN SINK OR THE | | | DISHWASHER CONNECTION OF A FOOD WASTE GRINDER. | | | D} PER FBC-2004 PLUMBING, SECTION 802.4 THE WASHING | | | MACHINE STANDPIPE SHALL EXTEND A MINIMUM OF 18 INCHES | | | AND A MAXIMUM OF 42 INCHES ABOVE THE TRAP WEIR. |
|