2007-04-19 08:31:51****************PROVISO****************
 A} BEDROOM #3 BATH TUB SHOULD BE A SHOWER PER SHEET
 A-2 FLOOR PLAN.
 B} PER FBC-2004 PLUMBING, SECTION 708.3.5 A TWO-WAY
 CLEANOUT IS REQUIRED AT THE JUNCTION OF THE BUILDING
 DRAIN AND BUILDING SEWER.
 C} PER FBC-2004 PLUMBING, SECTION 802.1.6 DOMESTIC
 DISHWASHING MACHINES SHALL DISCHARGE INTO A WYE-BRANCH
 FITTING ON THE TAILPIECE OF THE KITCHEN SINK OR THE
 DISHWASHER CONNECTION OF A FOOD WASTE GRINDER.
 D} PER FBC-2004 PLUMBING, SECTION 802.4 THE WASHING
 MACHINE STANDPIPE SHALL EXTEND A MINIMUM OF 18 INCHES
 AND A MAXIMUM OF 42 INCHES ABOVE THE TRAP WEIR.