| Date |
Text |
| 2007-02-16 11:36:05 | PLANNING AND ZONING DEPARTMENT |
| | |
| | ***FAILED*** |
| | |
| | 1. PLEASE PROVIDE RESPONSE TO COMMENTS IN WRITING. |
| | |
| | 2. PER ARTICLE XIX, DEFINITIONS, OF THE ZONING AND LAND |
| | DEVELOPMENT REGULATIONS, BUILDING HEIGHT MEANS THE |
| | VERTICAL DISTANCE FROM THE MEAN GRADE OF A LOT AT THE |
| | FRONTAGE OF THE BUILDING TO THE HIGHEST POINT OF THE |
| | TOP OF THE STRUCTURE OF A FLAT ROOF, OR TO THE DECK |
| | LINE OF A MANSARD ROOF, OR TO THE MID-HEIGHT LEVEL |
| | BETWEEN EAVES AND RIDGE FOR GABLE, HIP, AND GAMBREL |
| | ROOFS. |
| | A. PROPOSED RESIDENTIAL STRUCTURE EXCEEDS THE PERMITTED |
| | BUILDING HEIGHT PER THE SINGLE FAMILY HIGH DENSITY |
| | (SF14) RESIDENTIAL ZONING REGULATIONS (30 FEET), AS |
| | PLANS SHOW BUILDING HEIGHT MEASURED FROM THE FINISHED |
| | FLOOR. |
| | |
| | 3. PER SECTION 94-306, HEIGHT EXCEPTIONS, OF THE ZONING |
| | AND LAND DEVELOPMENT REGULATIONS, HEATING, VENTILATION |
| | AND AIR CONDITIONING EQUIPMENT, CHURCH STEEPLES, BELL |
| | TOWERS, FLAG POLES, CHIMNEYS, PARAPETS, STAIR |
| | ENCLOSURES, TANKS, DECORATIVE FEATURES, ELEVATOR |
| | HOISTWAYS OR EQUIPMENT, TELEVISION OR RADIO ANTENNAS, |
| | AND RELATED MECHANICAL OR FUNCTIONAL FEATURES, MAY |
| | EXCEED DISTRICT HEIGHT BY TEN (10) PERCENT. |
| | A. THE PARAPET, DECORATIVE FEATURES, AND CAST STONE |
| | URNS ON THE PROPOSED TOWER EXCEED THE BUILDING HEIGHT |
| | EXCEPTION OF 3 FEET (10 PERCENT). |
| | |
| | 4. PLEASE PROVIDE ELEVATION HEIGHT TO THE |
| | HIGHEST POINT FOR ALL ROOF STRUCTURES, INCLUDING |
| | ARCHITECTURAL FEATURES AND CHIMNEY. |
| | |
| | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q., OR ERIC |
| | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |