Plan Review Notes
Plan Review Notes For Permit 06061461
Permit Number 06061461
Review Stop B
Sequence Number 1
Notes
Date Text
2006-07-06 00:00:00 
  
 DENIED
  
 1) BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561) 233-5025 FOR MORE
 INFORMATION.
  
 2) THE STATE OF FLORIDA REQUIRES
 COLLECTION OF A RADON SURCHARGE ON ALL
 NEW CONSTRUCTION COMPUTED ON UNDER ROOF
 FLOOR SPACE PER 10D-91 FAC
  
 3) THE CLAIMED VALUATION ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 COST EXCLUDING LAND VALUE. OUR VALUATION
 REFERENCE IS ICC (BVD), MARSHALL-SWIFT
 AND MEANS COST ANALYSIS SERVICES PER
 108.3 FBC*
  
 4) THE PERMIT APPLICATION SHALL INCLUDE
 TWO COPIES OF EACH PRODUCT APPROVAL THAT
 IS RELEVANT PER 9B-72. THESE SHOULD
 INCLUDE THE FLORIDA STATE APPROVAL COVER
 PAGES, AND THE PRODUCT NOA THAT LISTS
 THE SYSTEM COMPONENTS/ FASTENER LIST
 PAGES, THE PAGES WITH THE CHOSEN
 ASSEMBLY/ SYSTEM TO BE USED AND THE
 GENERAL LIMITATIONS PAGE. ALL CAN BE
 FOUND ON WWW.FLORIDABUILDING.ORG
  
 A) PROVIDE MODIFIED BITUMEN ROOF
 COVERING PRODUCT APPROVAL FOR FLAT ROOF
  
 B) PROVIDE CAST-CRETE PRODUCT APPROVAL
  
 C) THERMA TRU FIBERGLASS DOOR IS NOT
 IMPACT RESISTANT AND WILL REQUIRE
 OPENING PROTECTIVES
  
 D) AMARR GARAGE DOOR HAS NO IMPACT
 RATING SHOWN IN THE PRODUCT APPROVALS
  
 5) THOSE PRODUCTS WHICH ARE REGULATED BY
 DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 6) PROVIDE AT A MINIMUM ONE BATHROOM ON
 THE MAIN FLOOR LEVEL WITH A ACCESSABLE
 DOOR (MIN 29" CLEAR) PER R322.1.1 FBC
  
 7) PROVIDE LINTEL SCHEDULE FOR
 CAST-CRETE LINTELS WITH LENGTHS USED FOR
 SPECIFIC DOOR OR WINDOW OPENINGS (MIN 4"
 END BEARING PER 2104.1.5 FBC)
  
 8) MAKE CORRECTIONS TO ROOF SHEATHING
 NAIL PATTERN FOR CORNER ZONE 3 PER
 2304.9.1 FBC
  
 9) SPIRAL STAIRS SHALL MEET ALL OF THE
 REQUIREMENTS OF R311.5.8.1 OR 1009.9.3
 FBC
  
 10) SUBMIT ENGINEERED TRUSS DRAWINGS
 THAT COMPLY WITH R802.10.1 FBC WITH
 PERMIT APPLICATION OR BEFORE
 INSTALLATION
  
 11) INDICATE TYPE AND VALUE OF WALL AND
 CEILING INSULATION
  
 12) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
  
 NOTE:
 FBC = FLORIDA BUILDING CODE 2004
 FBC* = WEST PALM BEACH ADMINISTATIVE
 AMMENDMENTS TO FBC
 FAC = FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 BLDG PLAN REVIEW