| Plan Review Notes For Permit 06061252 |
| Permit Number |
06061252 |
|
| Review Stop |
M |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2006-07-06 00:00:00 | *** DENIED *** | | | 1) MECHANICAL PLANS HAVE AN ARCHITECT'S | | | SEAL ON THEM AND REQUIRE HIS NAME AND | | | INFORMATION IN THE TITLE BLOCK, PER FAC | | | 61G1-16.004 . | | | | | | 2) PLEASE SUBMITMANUAL J CALCULATIONS, | | | PER 2004 FBC 13-607.1.ABC.1 . | | | | | | 3) ENERGY CALCULATIONS NEED TO BE SIGNED | | | BY OWNER/AGENT, PER 2004 FBC | | | 13-600.3.ABC.2 | | | | | | 4) BATHROOM EXHAUST FANS NEED TO BE 50 | | | CFM'S INTERMITTENT OR 20 CFM'S | | | CONTINUOUS, PER 2004 FBC/M 403.3 PLEASE | | | CORRECT. | | | | | | 5) SHOW LOCATION OF CLOTHES DRYER VENT | | | ON MECHANICAL PLANS, PLEASE OBSERVE | | | CLOTHES DRYER VENT TERMINATION MUST BE A | | | MIN. OF 4 FT. FROM A/C CONDENSER UNIT, | | | PER 2004 FBC/M 501.2 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|