| 2006-07-09 00:00:00 | | | | | | | DENIED | | | | | | 1) PROVIDE 2 COMPLETE SETS OF FLORIDA | | | PRODUCT APPROVALS.DRAWINGS ARE CUT OFF | | | AND MISSING INFORMATION | | | | | | 2) MARK THE DRAWINGS WITH THE TYPE OF | | | MOUNTING THAT WILL BE USED (EG. H TRACK | | | AT TOP AND STUD ANGLE AT BOTTOM), TYPE | | | OF ANCHOR THAT WILL BE USED ( BE | | | SPECIFIC, TAPCON, SOLID SET, ETC.), TYPE | | | OF CONST OF BUILDING ( WOOD, CONCRETE | | | BLOCK, ETC.) | | | | | | 3) PROVIDE A KEY PLAN SHOWING LOCATION | | | OF OPENINGS AND THERE SIZES, ALSO FILL | | | OUT A SHUTTER SCHEDULE SUCH AS EXAMPLE | | | ENCLOSED | | | | | | ADRIAN MORSE | | | BLDG PLAN REVIEW | | | 561-805-6716 |
|