Plan Review Notes
Plan Review Notes For Permit 06060672
Permit Number 06060672
Review Stop B
Sequence Number 1
Notes
Date Text
2006-08-08 00:00:00BUILDING PLAN REVIEW
 PERMIT: 06060672
 ADD: 2101 OKEECHOBEE BLVD
 CONT: ROEPNACK CORPORATION
 TEL: (954)691-2400
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
 --- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 NOTE!FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 1) MANUFACTURED BLDG PLANS APPROVED BY
 THE STATE ARE SHEETS 1-3. SHEET 4 IS THE
 FOUNDATION THAT MUST COMPLY WITH THE
 CODE IN EFFECT TODAY AS STATED ON SHEET
 # 4. SHEET # 4THAT THE FOUNDATION WAS
 DESIGNED UNDER THE 2004 FBC WRONG
 EDITION OF ASCE 7-(98).2004 FBC USES
 ASCE 7-02.SEE CHAPTER 35.
  
 2) A-101 THE HANDICAPPED RAMP LOWER
 LANDING IS MISSING THE 72" REQUIRED
 LANDING.11-4.8.4.(2) LANDINGS. ALL
 LANDINGS ON RAMPS SHALL NOT BE LESS THAN
 60" CLEAR, & THE BOTTOM OF EACH RAMP
 SHALL HAVE NOT LESS THAN 72" OF STRAIGHT
 & LEVEL CLEARENCE.
  
 3) A-101 GUARDRAIL/ HANDRAIL DETAIL
 INDICATES 2 1/4" CLEAR BETWEEN THE
 GUARDRAIL AND HANDRAIL.11-4.8.5(3) THE
 CLEAR SPACE BETWEEN THE HANDRAIL AND THE
 WALL SHALL BE 1? INCHES (38 MM).
  
 4) A-101 THE HANDRAIL ON BOTH THE FRONT
 AND REAR STAIR NEED TO BE RECONFIGURED
 TO THE DESIGN FOUND IN THE @004 FBC
 FIGURE 11-19A.
 11-9.4(2) HANDRAILS:2)IF HANDRAILS
 ARE NOT CONTINUOUS, THEY SHALL EXTEND AT
 LEAST 12 INCHES (305 MM) BEYOND THE TOP
 RISER AND AT LEAST 12 INCHES (305 MM)
 PLUS THE WIDTH OF ONE TREAD BEYOND THE
 BOTTOM RISER. AT THE TOP, THE EXTENSION
 SHALL BE PARALLEL WITH THE FLOOR OR
 GROUND SURFACE. AT THE BOTTOM, THE
 HANDRAIL SHALL CONTINUE TO SLOPE FOR A
 DISTANCE OF THE WIDTH OF ONE TREAD FROM
 THE BOTTOM RISER; THE REMAINDER OF THE
 EXTENSION SHALL BE HORIZONTAL [SEE
 FIGURE 11-19 (C) AND FIGURE 11-19 (D)].
 HANDRAIL EXTENSIONS SHALL COMPLY WITH
 SECTION 11-4.4 .
  
 5) CANOPY IN THE FRONT OF THE OFFICE
 TO BE UNDER A SEPERATE PERMIT.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  


Account Summary | Usage Policy | Privacy Policy