| Date |
Text |
| 2006-06-27 00:00:00 | |
| | 1) PROVIDE CLEAR AND DETAIL INSTRUCTIONS |
| | FOR THE REMOVAL OF THE AWNINGS DURING |
| | PERIODS OF 75MPH WINDS VELOCITY.OR THEY |
| | SHALL BE DESIGN TO WITH-STAND WINDS OF |
| | 140MPH. A NOTORIZE LETTER FROM THE OWNER |
| | IS REQUIRED STATING THAT THE AWNINGS |
| | WILL BE REMOVED OR REPOSITIONED DURING |
| | PERIODS OF HIGH WINDS OF 75MPH. |
| | |
| | 2)3105.4.2.1 |
| | THE WIND DESIGN LOADS FOR ANY FABRIC OR |
| | MEMBRANE-COVERED STRUCTURE DESIGNED WITH |
| | A QUICK REMOVAL OR BREAKAWAY MEMBRANE OR |
| | FABRIC AT WIND VELOCITIES OF 75 MPH, |
| | SHALL BE BASED ON THE FOLLOWING |
| | CRITERIA: |
| | 1. MINIMUM WIND VELOCITY OF 3-SECOND |
| | WIND GUST 90 MPH |
| | 2. IMPORTANCE FACTOR BASED ON LOW HAZARD |
| | TO HUMAN LIFE OF 0.77. |
| | 3. EXPOSURE CATEGORY B FOR OR C AS |
| | DEFINED IN CHAPTER 16 . FOR MORE |
| | INFORMATION SEE SEC. 3105 FBC. |
| | |
| | 3)2004 FL. BLD CODE 1603.1.4 THE |
| | FOLLOWING INFORMATION RELATED TO WIND |
| | SHALL BE SHOWN ON THE CONSTRUCTION |
| | DRAWINGS, |
| | 1)- BASIC WIND SPEED, MPH |
| | 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| | CATEGORY |
| | 3)- WIND EXPOSURE |
| | 4)- INTERNAL PRESSURE COEFFICIENT, |
| | 5)- COMPONENTS & CLADDING, THE DESIGN |
| | WIND PRESSURES IN TERMS OF PSF. |
| | )NOTE: PLANS REQUIRED TO BE SIGNED, |
| | DATED AND SEALED BY THE ARCHITECT, |
| | PLEASE SEE FS 481.221 AND FAC 61G1-16 |
| | |
| | |
| | 4) ENGINEERS SHALL LEGIBLY INDICATE |
| | THEIR NAME, ADDRESS AND LICENSE NUMBER |
| | ON EACH SHEET. IF PRACTICING THROUGH A |
| | DULY AUTHORIZED ENGINEERING BUSINESS, |
| | ENGIN- EERS, ENGINEERS SHALL LEGIBLY |
| | INDICATE THEIR NAME AND LICENSE NUMBER, |
| | AS WELL AS, THE NAME, ADDRESS AND |
| | CERTIFICATE OF AUTHORIZATION NUMBER OF |
| | THE ENGINEERING BUSINESS ON EACH SHEET. |
| | A TITLE BLOCK WILL SATISFY THIS |
| | REQUIREMENT. FAC 61G15-23.002(2) - FS |
| | 471.025 |
| | |
| | 5) FL S S 713.13 |
| | NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT BEFORE A |
| | PERMIT WILL BE ISSUED. NOTE: 713.13(2) |
| | IF THE WORK DESCRIBED IN THE NOTICE OF |
| | COMMENCEMENT IS NOT ACTUALLY COMMENCED |
| | WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | TEL:(561)805-6726 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |