2007-09-06 07:32:07** DENIED **
  
 1) NOTE: PLEASE SEE A KITCHEN SMALL APPLIANCE
 RECEPTACLE A-7 IS BEING SHOWN WITH A LOAD OF 450VA WHEN
 THIS IS REQUIRED TO BE FIGURED AS ONE OR MORE OF THE
 SMALL APPLIANCE CIRCUITS.
 220.16, 210.52B1, 210.11C1
 NEED TO UPDATE THE PANEL SCHEDULE AND LOAD
 CALCULATIONS.
  
 ** PLEASE BE SURE TO SUBMIT LETTERS BACK WITH THE
 PLANS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]