| 2006-06-22 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 06060297 |
| | ADD: 2916 S DIXIE HWY |
| | CONT: TERRA CONSTRUCTION |
| | TEL: (561)329-7676 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | --- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 1) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION |
| | THAT IS REQUIRED FOR RECORD |
| | KEEPING & FOR CERTIFICATE OF OCCUPANCY: |
| | A) THE EDITION OFTHE CODE UNDER WHICH |
| | THE PERMIT WAS ISSUED. |
| | FLORIDA BUILDING CODE/ 2004 |
| | EXISTING BUILDING CODE/ 2004 |
| | CLASSIFICATION OF WORK, |
| | LEVEL 1,2 OR 3. |
| | B) THE USE AND OCCUPANCY, IN ACCORDANCE |
| | WITH THE PROVISIONS OF CHAPTER 3. |
| | C) THE TYPE OF CONSTRUCTION AS DEFINED |
| | IN CHAPTER 6, TABLE 601. |
| | D) THE DESIGN OCCUPANT LOAD, SEE 1004. |
| | IS THIS A CHANGE OF OCCUPANCY? |
| | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS |
| | PROVIDED, WHETHER THE SPRINKLER |
| | SYSTEM IS REQUIRED. |
| | F) ANY SPECIAL STIPULATIONS & CONDITIONS |
| | |
| | OF THE BUILDING PERMIT. |
| | |
| | 2) SHEET A-1 OVERHEAD DOOR INFILL, PLANS |
| | INDICATE THE USE OF 22 GA. STEEL STUDS. |
| | THIS GAUGE STUDS ARE FOR INTERIOR USE |
| | ONLY. STRUCTURAL GAUGE FRAMING IS 18 |
| | GAUGE AND HEAVIER.ASTM C955 LOAD BEARING |
| | STEEL STUDS, TABLE 22506.2. |
| | |
| | 3) SAME DETAIL INDICATES THE USE OF |
| | PLYWOOD SHEATHING, SEE 2304.11.2.5 WOOD |
| | SIDING. |
| | CLEARANCE BETWEEN WOOD SIDING AND EARTH |
| | ON THE EXTERIOR OF A BUILDING SHALL NOT |
| | BE LESS THAN 6 INCHES (152 MM) EXCEPT |
| | WHERE SIDING, SHEATHING AND WALL FRAMING |
| | ARE OF NATURALLY DURABLE OR |
| | PRESERVATIVE-TREATED WOOD . |
| | 2304.9.5 FASTENERS IN PRESERVATIVE |
| | TREATED AND FIRE-RETARDANT-TREATED WOOD |
| | . FASTENERS FOR PRESERVATIVE TREATED AND |
| | FIRE-RETARDANT-TREATED WOOD SHALL BE OF |
| | HOT-DIPPED ZINC-COATED GALVANIZED STEEL, |
| | STAINLESS STEEL, SILICON BRONZE OR |
| | COPPER. FASTENINGS FOR WOOD FOUNDATIONS |
| | SHALL BE AS REQUIRED IN AF&PA TECHNICAL |
| | REPORT NO. 7. |
| | |
| | 4) OFFICE DOOR(A) MISSING 18" CLEARENCE |
| | 11-4.13.6 MANEUVERING CLEARENCES |
| | AT DOORS. MINIMUM MANEUVERING CLEARENCES |
| | AT DOORS THAT ARE NOT AUTOMATIC OR |
| | POWER-ASSISTED SHALL BE AS SHOWN IN |
| | FIG. 25. THE FLOOR OR GROUND AREA WITH |
| | IN THE REQUIRED CLEARENCES SHALL BE |
| | CLEAR & LEVEL. |
| | |
| | 5) UNISEX RESTROOM DOOR:11-4.22.2 DOORS. |
| | |
| | (1)ALL DOORS TO ACCESSIBLE TOILET |
| | ROOMS SHALL COMPLY WITH SECTION 11-4.13 |
| | . DOORS SHALL NOT SWING INTO THE CLEAR |
| | FLOOR SPACE REQUIRED FOR ANY |
| | FIXTURE.11-4.19.3 CLEAR FLOOR SPACE. |
| | A CLEAR FLOOR SPACE 30 INCHES BY 48 |
| | INCHES (760 MM BY 1219 MM) COMPLYING |
| | WITH SECTION 11-4.2.4 SHALL BE PROVIDED |
| | IN FRONT OF A LAVATORY TO ALLOW FORWARD |
| | APPROACH. SUCH CLEAR FLOOR SPACE SHALL |
| | ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE |
| | AND SHALL EXTEND A MAXIMUM OF 19 INCHES |
| | (485 MM) UNDERNEATH THE LAVATORY (SEE |
| | FIGURE 11-32 ). |
| | |
| | 6) SHOWER:11-4.21.7 CURBS. |
| | IF PROVIDED, CURBS IN SHOWER STALLS 36 |
| | INCHES BY 36 INCHES (915 MM BY 915 MM) |
| | SHALL BE NO HIGHER THAN ? INCH (13 MM). |
| | SHOWER STALLS THAT ARE 30 INCHES BY 60 |
| | INCHES (760 MM BY 1525 MM) MINIMUM SHALL |
| | NOT HAVE CURBS. |
| | |
| | 7) EXISTING ENTRY DOORS APPEAR TO BE |
| | APPROXIMATELY 2'-0" WIDE.ONE ENTRANCE |
| | HAS STAIRS, DOES THE OTHER ENTRANCE HAVE |
| | AN ACCESSIBLE ENTRANCE SINGLE DOOR 3'-0" |
| | WIDE? |
| | 11-4.1.6(2) DUTY TO PROVIDE AN |
| | ACCESSIBLE PATH OF TRAVEL TO ALTERED |
| | AREAS SHALL BE DEEMED DISPROPORTIONATE |
| | TO THE OVERALL ALTERATION WHEN THE COST |
| | EXCEEDS 20 % OF THE COST OF THE ALTERA- |
| | TION TO THE PRIMARY FUNCTION AREA. |
| | (A)(I) AN ACCESSIBLE ENTRANCE |
| | (II) AN ACCESSIBLE ROUTE |
| | (III) AT LEAST ONE ACCESSIBLE REST- |
| | ROOM FOR EACH SEX OR A SINGLE |
| | UNISEX RESTROOM |
| | (IIII) ACCESSIBLE TELEPHONE |
| | (IV) ELEMENTS SUCH AS PARKING, STOR- |
| | AGE OR ALARMS. |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |