| 2007-03-31 13:24:56 | |
| | |
| | DENIED |
| | |
| | ****NOTE**** |
| | THE FOLLOWING COMMENTS FROM THE 2ND BUILDING REVIEW |
| | WERE NOT ADDRESSED. |
| | |
| | 1) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT IS REQUIRED PRIOR TO |
| | A PERMIT BEING ISSUED |
| | |
| | 3) SUBMIT ENERGY CALC'S PER 13-101.2.2 |
| | FBC. BE SURE THAT THEY ARE SIGNED AND |
| | DATED BY PREPARER AND OWNER/AGENT PRIOR |
| | TO SUBMITTAL. *****NOT SIGNED AND DATED BY |
| | OWNER/AGENT****** |
| | |
| | 6) THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9B-72 |
| | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL PER 106.3.3 FBC*. |
| | ******REVIEWED AND APPROVED BY PERSON RESPONSIBLE FOR |
| | DRAWINGS******* |
| | |
| | 7) SUBMIT ENGINEERED TRUSS DRAWINGS THAT |
| | COMPLY WITH R802.10.1 FBC WITH PERMIT |
| | APPLICATION OR BEFORE INSTALLATION THAT |
| | HAVE BEEN REVIEWED AND APPROVED BY THE |
| | DESIGNER OF RECORD. |
| | |
| | 9) PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN |
| | COMPLIANCE WITH THE REQUIREMENTS OF R403.1 ******THE |
| | DRAINAGE PROVISION IS TO SHOW POSITIVE DRAINAGE AWAY |
| | FROM NEW STRUCTURE AND ALSO SHOW THAT DOES NOT FLOW |
| | ONTO ADJOINING PROPERTY****** |
| | |
| | ******NEW COMMENTS****** |
| | |
| | 1) THE PROVIDED ATTIC ACCESS IS THROUGH THE PROPOSED |
| | GIRDER BEAM PLEASE RELOCATE TO AN AREA THAT PROVIDES |
| | 30" OF HEADROOM ABOVE ACCESS. |
| | |
| | 2) UNDER THE EXISTING BUILDING CODE ADDITIONS ARE |
| | TREATED AS NEW CONSTRUCTION AND THE ACCESSIBILITY |
| | REQUIREMENTS OF ONE BATHROOM WITH A MIN 29" CLEAR |
| | OPENING WITH DOOR AT 90 DEGREES IS REQUIRE PER R322.1.1 |
| | FBC |
| | |
| | 3) UNDER THE EXISTING BUILDING CODE ADDITIONS, SMOKE |
| | ALARMS SHALL BE PROVIDED IN THE EXISTING PORTIONS OF |
| | THE BUILDING PER 904.2 FBC (EXISTING) |
| | |
| | 4) THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA |
| | STATE PRODUCT APPROVAL COVER |
| | SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON |
| | WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT |
| | SUBMITTED APPLICATIONS WILL BE DENIED. |
| | PLEASE NOTE THAT I HAVE PRINTED THESE FOR YOUR WINDOWS |
| | AND PRECAST LINTELS |
| | |
| | 5) PROVIDE NEW UPDATED MIAMI-DADE NOA'S FOR THE |
| | OAKRIDGE PRO 40 SHINGLES AS THIS NOA HAS EXPIRED. ALSO |
| | A NOA WILL BE REQUIRED FOR THE FLAT ROOF I WOULD |
| | SUGGEST THAT YOUR ROOFING CONTRACTOR SUPPLIES YOU WITH |
| | THIS PRODUCT APPROVAL AS THERE ARE THOUSANDS OF |
| | VARIATIONS AND THE EXACT ONE MUST BE CHOSEN AND |
| | INSTALLED TO PASS INSPECTION. PROVIDE PRODUCT APPROVAL |
| | FOR MULLION WHERE 2 OR MORE WINDOWS ARE JOINED TOGETHER |
| | AS IN MASTER BEDROOM. |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |
| | |
| | |
| | |
| | |
| | |
| | |