| 2006-06-06 00:00:00 | DENIED |
| | |
| | |
| | 1.BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 2.BASED ON ICC BUILDING VALUATION DATA |
| | THE PERMIT VALUE HAS BEEN REVISED TO |
| | $136,648.ADDITIONAL PERMIT FEES ARE |
| | DUE. |
| | |
| | 3. SIGN OWNER/AGENT ON ENERGY CALCS. |
| | |
| | 4.PRODUCT APPROVALS REQUIRED FOR |
| | STRAPS AND TIEDOWNS, ROOFING AND |
| | LINTELS. |
| | |
| | 5.ALL PRODUCT APPROVALS SUBMITTED WITH |
| | QUALITY ASSURANCE SHALL HAVE THE |
| | FOLLOWING STATE APPROVAL ATTACHED. |
| | |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A STATE PRODUCT APPROVAL |
| | SHEETS THAT LISTS THE PRODUCT IDENTITY |
| | NUMBER FROM THE STATE. IF THE PRODUCT |
| | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT |
| | AN APPLICATION FOR LOCAL PRODUCT |
| | APPROVAL OR SITE SPECIFIC FORM PER RULE |
| | 9B-72. SEE ATTACHMENT. |
| | WWW.FLORIDABUILDING.ORG |
| | |
| | 6.THOSE PRODUCT APPROVALS WHICH ARE |
| | REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL.WPB |
| | AMENDMENT TO FBC 106.3.3. |
| | |
| | 7.SUBMIT TWO SETS OF TRUSS DRAWINGS |
| | FOR REVIEW PER 2004 FBC R-802.10.1 |
| | |
| | 8.BEDROOM EMERGENCY ESCAPE RESCUE |
| | OPENING SIZES SHALL COMPLY WITH |
| | R310.1.1, R310.1.2 AND R310.1.3.SH24 |
| | DOES NOT MEET THE REQUIREMENTS OF THIS |
| | SECTION. |
| | |
| | 9.ROOF SHEATHING SHALL COMPLY WITH FBC |
| | 2304.9.1 #31 |
| | |
| | 10.SHOW SIZE AND LOCATION OF ATTIC |
| | ACCESS COMPLYING WITH FBC R807.1 |
| | |
| | 11.R401.3 DRAINAGE. |
| | SURFACE DRAINAGE SHALL BE DIVERTED TO A |
| | STORM SEWER CONVEYANCE OR OTHER APPROVED |
| | POINT OF COLLECTION SO AS TO NOT CREATE |
| | A HAZARD. LOTS SHALL BE GRADED SO AS TO |
| | DRAIN SURFACE WATER AWAY FROM FOUNDATION |
| | WALLS. THE GRADE AWAY FROM FOUNDATION |
| | WALLS SHALL FALL A MINIMUM OF 6 INCHES |
| | WITHIN THE FIRST 10 FEET.SHOW DETAIL |
| | ON PLANS. |
| | |
| | |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. SUBMIT ONE COPY OF |
| | OLD PAGES FOR REFERENCE. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET |
| | OR SPECIFICATION PAGE WHERE THE CHANGES |
| | CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |