| Date |
Text |
| 2007-11-08 14:14:51 | BUILDING PLAN REVIEW |
| | PERMIT: 06050604 |
| | ADD: 1810 S DIXIE HWY |
| | CONT: BATTEN CONSTRUCTION |
| | TEL: (561)662-0309 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ NOV. 21 2005 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVISION REVIEW |
| | ACTION: DENIED |
| | |
| | 1A) SITE PLAN, INDICATES THE DELETION OF THE |
| | HANDICAPPED RAMP TO SPACE # 1 AND THE NEW DOOR TO THE |
| | REAR OF SPACE # 1 IS ALSO NOT ON AN ACCESSIBLE ROUTE |
| | PLEASE SEE , 11-4.1.6(A) NO ALTERATION SHALL BE |
| | UNDERTAKEN WHICH DECREASES OR HAS THE EFFECT OF |
| | DECRESING ACCESSIBILITY OR USABILITY OF A BUILDING. |
| | |
| | 1B) SITE PLAN, THE TENANT SEPERATION LINE ON THIS SHEET |
| | DOES NOT MATCH WITH SHEET# 3. IT APPEARS ON SHEET # 3 |
| | TENANT SPACE # 2 HAS THE FRONT ENTRY DELETED AND THE |
| | INTERIOR FOYER. THE NEW ENTRY WILDEMERE AVENUE BUT THE |
| | SITE PLAN HAS NOT BEEN UPDATED |
| | TO REFLECT A NEW ENTRY OR WALKWAY FROM THE PUBLIC WAY. |
| | 11-4.1.6(A) NO ALTERATION SHALL BE UNDERTAKEN WHICH |
| | DECREASES OR HAS THE EFFECT OF DECRESING ACCESSIBILITY |
| | OR USABILITY OF A BUILDING. |
| | |
| | 1C) SITE PLAN, PLEASE UPDATE THE SITE PLAN SHOWING AN |
| | ACCESSIBLE ROUTE TO BOTH SPACE NUMBER 1 & 2. THE ISSUE |
| | NOW CREATED WITH THE REMOVAL OF THE HANDICAPPED RAMP |
| | AND NOT INDICATING THE ACCESSIBLE ROUTE TO SPACE NUMBER |
| | ONE WHERE THE NEW DOOR IS |
| | LOCATED IN THE REAR OF THE BUILDING IT WILL CAUSE THE |
| | DISABLED INDIVIDUAL TO TRAVEL BEHIND PARKED VEHICLE, |
| | PLEASE SEE 11-4.6.2 ACCESSIBLE PARKING SPACES SERVING A |
| | PARTICULAR BUILDING SHALL BE LOCATED ON THE SHOREST |
| | SAFELY ACCESSIBLE ROUTE TRAVELED FROM ADJACENT PARKING |
| | TO AN ACCESSIBLE ENTRANCE. WITH THE DELETION OF THE |
| | FRONT ENTRY LOBBY IT COULD BE ARGUED THAT EQUIVALENT |
| | FACILITATION 11-2.2 IS NOT BEING MET, |
| | |
| | 2) SHEET NUMBER THREE PLEASE SHOW THE REVISION TO THE |
| | PLAN HIGHLIGHT WITH EITHER A CLOUD OR DELTA WHATTHE |
| | SCOPE OF WORK TO BE COMPLETED UNDER THIS REVISION, |
| | PLANS ARE UNCLEAR, EXAMPLE IF THERE IS TO BE NO TENANT |
| | BUILDOUT IN SPACE # 1 THEN DO NOT SHOW A |
| | FINISHED INTERIOR, OR IF THE FRONT ENTRY AND LOBBY ARE |
| | DELETED THEN REMOVE FROM THE PROJECT. 106.1.1 |
| | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| | PROVISIONS OF THIS CODE.\ |
| | |
| | 3)SHEET # 5 INDICATES THE REMOVAL OF ROOF DRAINS, AND |
| | SHEET # 10 INDICATES THE REMOVAL OF THE PARAPET, PLEASE |
| | SHOW HOW AND OR WHERE THE WATER WILL BE REOMVED FROM |
| | THE ROOF. EITHER SHOW THE SLOPE WHERE ATER WILL OVER |
| | FLOW THE EDGE OF THE ROOF, WHERE A GUTTER AND ROOF |
| | LEADERS1503.4 ROOF DRAINAGE, 1503.4.1 GUTTERS. 1503.3.6 |
| | PROTECTION AGAINST DECAY & TERMITES. CONDENSATE LINES & |
| | ROOF DOWN SPOUTS SHALL DISCHARGE AT LEAST 1 FT. AWAY |
| | FROM THE STRUCTURE SIDEWALL, WHETHER BY UNDERGROUND |
| | PIPING, TAIL EXTENSIONS, OR SPLASH BLOCKS. 102.1* |
| | WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS OF THIS |
| | CODE SPECIFY DIFFERENT MATERIALS, METHODS OF |
| | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST |
| | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT |
| | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC |
| | REQUIREMENT, THE SPECIFIC |
| | REQUIREMENT SHALL BE APPLICABLE. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAILCOMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |