2006-06-13 00:00:00DENIED;
  
 1. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2004 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1(4). INCLUDE
 EXISTING GAS APPLIANCES AND THE LONGEST
 RUN. NEW HEATERS AND DRYER WILL BE ADDED
 TO OLD SYSTEM.
 2. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2004 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 3. SUBMIT MANUFACTURE SHEETS FOR WATER
 HEATERSTO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2. MOST
 INST. HOT HEATERS ARE AROUND 200,000
 BTU'S.
 4. UNDER GROUND GAS PIPE TO BE (PE)
 POLYETHYLENE PLASTIC PIPE.