Plan Review Notes
Plan Review Notes For Permit 06050493
Permit Number 06050493
Review Stop P
Sequence Number 1
Notes
Date Text
2006-06-05 00:00:00******DENIED******
 REFERENCE: FBC-2004 SEC. 424.2 SWIMMING
 POOLS OR FBC-2004 RESIDENTIAL SEC.R4101
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FROM PLUMBING PLAN REVIEW FOR A PERMIT:
  
 1) FBC-2004 SEC. 424.2.6.6.5, OR
 FBCR-2004 SEC. R4101.6.6.5 WHERE
 PROVIDED, THE VACUUM OR PRESSURE CLEANER
 FITTING SHALL BE LOCATED AT LEAST 6" AND
 NOT GREATER THAN 12" BELOW THE MINIMUM
 OPER- ATING WATER LEVEL OR AS AN
 ATTACHMENT TO THE SKIMMER.(MANUFACTURER
 CUT SHEETS REQUIRED OR ADD MAKE AND
 MODEL NUMBER TO PRINTS)
 2) FBC-2004 SEC. 424.6.6 OR FBC-2004
 RESIDENTIAL SEC. R4101.6.6: ENTRAPMENT
 PROTECTION FOR SUCTION INLETS. PLEASE
 SUBMIT AN ENGINEERED TABLE FOR "VENT
 PIPE MAXIMUM LENGTH" INDICATING PUMP
 SIZES, AVERAGE FLOW, AND MAXIMUM LENGTH
 OF THE1-1/2" PVC VENT PIPE, FROM WHERE
 IT STARTS TO WHERE IT ENDS UP, COMPLYING
 WITH THE THREE SECOND RELEASE.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  