| Plan Review Notes For Permit 06050236 |
| Permit Number |
06050236 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2006-05-15 00:00:00 | DENIED; | | | 1.SANITARY RISER DIAGRAM; MECHANICAL | | | VENTS CAN ONLY BE USED ON THE TOP 4 | | | FLOORS, PER. FBC-2004 PLUMBING SEC. | | | 917.3.1. IF SUITE IS MORE THAN 4 FLOORS | | | FROM TOP VENT MUST BE RUN TO VENT STACK. | | | 2.BREAK SINK IS REQUIRED TO HAVE A | | | FRONTAL APPROACH. MUST COMPLY WITH | | | FBC-2004 CHAPTER 11. SEC'S ; | | | 11-4.24.3 KNEE CLEARANCE 27" HIGH | | | 30" WIDEAND 19" DEEP. | | | 11-4.24.4 SINK TO BE MAX. OF 6 1/2" | | | DEEP. | | | 11-4.24.6 RAP EXPOSED PIPES. | | | 11-4.24.7 FAUCET TO BE LEVER | | | OPERATED. | | | SHOW A DETAIL ON PLANS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 | | | | | | |
|