| Date |
Text |
| 2007-08-26 13:28:50 | BUILDING PLAN REVIEW |
| | PERMIT: 06040957 |
| | ADD: 525 OKEECHOBEE BLVD |
| | CONT: BALFOUR BEATTY CONSTRTION |
| | TEL: (561)718-0935 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | SHOP DRAWINGREVIEW : DIXIE METAL PRODUCTS |
| | ACTION: DENIED |
| | |
| | SUBMITTAL: |
| | |
| | 1)SHEET14-1 & 15-2 BOTH INDICATE THE HANDRAIL HAVE |
| | A CLEARANCE OF 2 1/4", PLEASE CORRECT. |
| | 2004 FBC BUILDING11-4.9.4(3) THE CLEAR SPACE BETWEEN |
| | HANDRAILS AND WALL SHALLBE 1 1/2". |
| | |
| | 2) SHEET 15-E1 SECTION A INDICATES 3/8" PICKETS BUT THE |
| | 4 1/2" BETWEEN DOES NOT INDICATE IF THIS IS THE SPACE |
| | BETWEEN OR CENTER TO CENTER. |
| | 1012.3 OPENING LIMITATIONS. OPEN GUARDS SHALL HAVE |
| | BALUSTERS OR ORNAMENTAL PATTERNS SUCH THAT A |
| | 4-INCH-DIAMETER (102 MM) SPHERE CANNOT PASS THROUGH ANY |
| | OPENING UP TO A HEIGHT OF 34 INCHES (864 MM). FROM A |
| | HEIGHT OF 34 INCHES (864 MM) TO 42 INCHES (1067 MM) |
| | ABOVE THE ADJACENT WALKING SURFACES, A SPHERE 8 INCHES |
| | (203 MM) IN DIAMETER SHALL NOT PASS. |
| | EXCEPTIONS: |
| | 1.THE TRIANGULAR OPENINGS FORMED BY THE RISER, |
| | TREAD AND BOTTOM RAIL AT THE OPEN SIDE OF A STAIRWAY |
| | SHALL BE OF A MAXIMUM SIZE SUCH THAT A SPHERE OF 6 |
| | INCHES (152 MM) IN DIAMETER CANNOT PASS THROUGH THE |
| | OPENING. |
| | |
| | 3) SHEET 15-E1 SECTION C PICKETS DO NOT PROVIDE ANY |
| | INFORMATION NOTR DOES THETRIANGLE FORMED BY THE RISE, |
| | RUN OF STEP AND BOTTOM RAILING MEMBER. |
| | SEE 1012.3 ABOVE FOR OPENING LIMITATION. |
| | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS |
| | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF |
| | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST |
| | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT |
| | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC |
| | REQUIREMENT, THE SPECIFIC |
| | REQUIREMENT SHALL BE APPLICABLE. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | |
| | |
| | |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |
| | |