Plan Review Notes
Plan Review Notes For Permit 06040955
Permit Number 06040955
Review Stop B
Sequence Number 4
Notes
Date Text
2008-11-07 10:53:39****CORRECTIONS****
 ****FIRST PERMIT PLAN REVIEW (CONVERTED FROM PLAN CHECK
 TO PERMIT APPLICATION)****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004EXISTING BUILDING CODE
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 COMMENTS FROM PREVIOUS LISTS, NOT ADDRESSED
  
 1.) A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED, FS713.
  
 2.) IMPACT FEES MAY BE OWED TO PALM
 BEACH COUNTY. THE PLANS MUST BE STAMPED
 AND THE RECEIPT ATTACHED TO THE
 APPLICATION. 233-5025.
  
 **10/10, CONFIRMED WITH PALM BEACH COUNTY, IMPACT FEE
 ASSESSMENT REQUIRED***
  
 3.) DECLARE THE LEVEL OF ALTERATION,
 FBC EB 301.
  
 4.) DECLARE OCCUPANCY FBC309.
  
 M AND B WAS DECLARED. PROVIDE SF AREA FOR EACH
 OCCUPANCY SO THAT OCCUPANT LOAD CAN BE DETERMINED.
  
 4TH REVIEW, APPEARS TO BE M. PLEASE EXPLAIN WHY PLANS
 STATE B M. SEE FBC309.1.
  
 5.) DECLARE AN OCCUPANT LOAD, FBC10.
  
 HOW HAVE YOU ARRIVED AT AN OCCUPANT LOAD OF 16, 1000/8
 X 1980? SEE FBC1004.1, MUST USE EITHER DESIGN LOAD OR
 BASED ON FBC TABLE 1004.1.2, WHICHEVER IS GREATER. M
 AND B HAVE DIFFERENT OCCUPANT LOADS. SEE FBC309; IT
 APPEARS THAT HIS IS M OCCUPANCY, NOT B. PROVIDE MORE
 INFORMATION IN REGARDS TO THE USE OF THIS BUILDING TO
 JUSTIFY THE B OCCUPANCY CLASSIFICATION.
  
 4TH REVIEW, OCCUPANT LOAD SHOULD BE SF AREA / 30 PER
 FBC TABLE 1004.1.2. PLEASE REVISE OR EXPLAIN OCCUPANT
 LOAD.
  
 6.) ADDRESSED.
  
 7.) PRODUCT APPROVALS REQUIRED FOR THE
 STOREFRONT AND DOORS. FLORIDA STATE OR
 LOCAL PRODUCT APPROVALS REQUIRED
 FAC9B72. WWW.FLORIDABUILDING.ORG
  
 4TH REVIEW, NO PRODUCT APPROVALS SUBMITTED. ALSO NOTE
 THAT A/C STAND IS SHOWN ON M SHEETS; PRODUCT APPROVAL
 REQUIRED. RESOLVE CONFLICTS/INCONSISTENCIES BETWEEN
 PLANS AND PRODUCT APPRPOVAL, IF ANY, PRIOR TO
 RESUBMITTAL.
  
 8.) PRODUCT APPROVALS ARE TO BE
 REVIEWED BY DESIGNER OF RECORD,
 FBC*106.3.3.
  
 10-16.) ADDRESSED.
  
 17.) PROVIDE ENERGY CALCS AND SIGN IN
 ALL APPLICABLE PLACES, INCLUDING THE
 OWNER/AGENT LINE FBC13-103.1.
  
 INCLUDE THE STRUCTURAL ENGINEER TO CERTIFY ENERGY
 COMPLIANCE, FBC13-103.1.1.1 AS HE IS REPONSIBLE FOR THE
 BUILDING SHELL.
  
 18-19.) ADDRESSED.
  
 20.) M2 WAS REVISED AS PER PREVIOUS
 LIST, BUT STILL REFERS TO HIGH VELOCITY.
 CITY OF WEST PALM BEACH IS NOT IN THE
 HIGH VELOCITY ZONE.
  
 THE CHART IS FROM HVHZ, PLEASE USE THE APPROPRIATE
 CHART FROM FBC TABLE 1509.7. ALSO, THERE IS A TYPO ON
 LINE 3 (27).
  
 4TH REVIEW, REMOVE REFERENCE TO HVHZ.
  
 21.) WHEN RESUBMITTING, PLEASE REMOVE
 OLD SHEETS.
  
 BUT PLEASE PROVIDE THEM FOR REFERENCE.
  
 4TH REVIEW, OLD SHEETS NOT SUBMITTED. A SET HAS BEEN
 RETAINED.
  
 22.) N/A
  
 23.) IT APPEARS THAT MANY COMMENTS WERE
 NOT ADDRESSED. TO EXPEDITE PLAN REVIEW,
 PLEASE INCLUDE A RESPONSE LETTER
 INDICATING HOW AND WHERE EACH ITEM WAS
 ADDRESSED.
  
 PLEASE SUBMIT BOTH THE OLD SHEETS AND A RESPONSE LETTER
 WHEN RESUBMITTING. FAILURE TO DO SO REQUIRES A
 COMPLETELY NEW PLAN REVIEW AND INCREASES THE
 POSSIBILITY OF NEW COMMENTS.
  
 24-25.) ADDRESSED.
  
 26.) ALL CHANGES ARE TO BE CLOUDED.
  
 27.) IT APPEARS THAT THE ENGINEER HAS NOT DELCARED THE
 CORRECT OCCUPANT LOAD AND TWO EXITS ARE REQUIRED. THE
 TWO EXITS ARE TO BE REMOTELY LOCATED, FBC1014.2.1. THIS
 REQUIREMENT CANNOT BE DETERMINED DUE TO THE ENGINEER'S
 FAILURE TO ADDRESS THE COMMENT REGARDING OCCUPANT LOAD
 AND OCCUPANCY CLASSIFICATION.
  
 28.) SOMEONE HAS REVISED THE PLAN A1B. INCORPORATE
 CHANGES INTO THE SIGNED AND SEALED PLAN. SOMEONE WROTE
 "SLIDING" DOOR (RATHER THAN SWINGING). THE DOOR IS TO
 COMPLY WITH FBC1008.1.3.3; NOTE REQUIREMENTS ON PLAN
 AND REVISE ELECTRIC SHEETS.
  
 29.) THE PLANS DO NOT SHOW THE ISO BOARD REQUIRED FOR
 THE WALLS (ENERGY CALCS). PLEASE CORRELATE. NOTE
 EXISTING CONDITIONS FOR EXISTING WALLS. ALL INFORMATION
 IS TO BE ON THE PLAN IF A TYPED NAME IS USED IN LIEU OF
 A SIGNATURE, SEE FBC13-103.1.1.1.
  
 30.) SHEET 2, WHAT DO THE ARROWS REPRESENT ON THE
 ACCESSIBLE PARKING DETAIL?
  