| Date |
Text |
| 2006-05-26 00:00:00 | ******DENIED****** |
| | REFERENCE: FBC-2004 PLUMBING |
| | FBC-2004 CHAPTER 1 |
| | FLORIDA ADMINISTRATIVE CODE |
| | |
| | THE FOLLOWING INFORMATION IS REQUIRED |
| | FOR PLUMBING PLAN REVIEW FOR A PERMIT: |
| | |
| | 1. THE PRINTS SUBMITTED ARE COPIES WITH |
| | NO RAISED SEAL THE FOLLOWING IS REQUIRED |
| | BY STATE STATUTES. |
| | (A) 106.1 SUBMITTAL DOCUMENTS. IF THE |
| | DESIGN PROFESSIONAL IS AN ARCHITECT OR |
| | ENGINEER LEGALLY REGISTERED UNDER THE |
| | LAWS OF THIS STATE REGULATING THE |
| | PRACTICE OF ARCHITECTURE AS PROVIDED FOR |
| | IN CHAPTER 481, FLORIDA STATUTES, PART |
| | 1, OR ENGINEERING AS PROVIDED FOR IN |
| | CHAPTER 471, FLORIDA STATUTES, THEN HE |
| | OR SHE SHALL AFFIX HIS OR HER SEAL, |
| | SIGNATURE AND DATE TO SAID DRAWINGS, |
| | SPECIFICATIONS AND ACCOMPANYING DATA, AS |
| | REQUIRED BY FLORIDA STATUTES. |
| | 2. THE SANITARY ISOMETRIC RISER DIAGRAM |
| | DOEN'T REFLECT THE FLOOR PLAN, FLOOR |
| | PLAN ON SHEET 1 INDICATES A SHOWER, AND |
| | THE RISER DIAGRAM ON SHEET 5 INDICATES A |
| | TUB PLEASE CORRELATE PER THE FOLLOWING |
| | (A) 106.1.1 INFORMATION ON CONSTRUCTION |
| | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL |
| | BE OF SUFFICIENT CLARITY TO INDICATE THE |
| | LOCATION, NATURE AND EXTENT OF THE WORK |
| | PROPOSED AND SHOW IN DETAIL THAT IT WILL |
| | CONFORM TO THE PROVISIONS OF THIS CODE |
| | AND RELAVENT LAWS, ORDINANCES, RULES AND |
| | REGULATIONS, AS DETERMINED BY THE |
| | BUILDING OFFICIAL. |
| | 3. ON SHEET 5 THE SANITARY RISER DIAGRAM |
| | INDICATES A 3" TRAP FOR THE W/C, THIS |
| | TRAP ISN'T REQUIRED BECAUSE THE W/C HAS |
| | AN INTREGRAL TRAP. PLEASE REMOVE 3" TRAP |
| | FOR RESUBMITTAL. ALSO ON SHEET 5 RUNNING |
| | TRAPS ARE INDICATED FOR THE LAV AND |
| | SHOWER RUNNING TRAPS ARE ILLEGAL PER |
| | SEC. 1002.3 PLEASE REMOVE RUNNING TRAPS |
| | FOR RESUBMITTAL. |
| | 4. THE FOLLOWING IS REQUIRED FOR CLEAN- |
| | OUTS ON THE RISER DIAGRAM ON SHEET 5. |
| | (A) 708.3.4 BASE OF STACK. A CLEANOUT |
| | SHALL BE PROVIDED AT THE BASE OF EACH |
| | WASTE OR SOIL STACK |
| | |
| | END OF COMMENTS: |
| | |
| | REVIEW BY MIKE PERSON |
| | (561) 805-6730 |
| | FAX (561) 805-6731 |
| | E-MAIL [email protected] |
| | UNDER SUPERVISION OF K.STEVENS |
| | (561) 805-6721 |
| | |
| | |
| | |