| Plan Review Notes For Permit 06040766 |
| Permit Number |
06040766 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2006-05-09 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | 1.)THE PLANS APPEAR CODE COMPLIANT | | | WITH THE EXCEPTION OF THE WIND PRESSURES | | | ON THE INSTALLATION SCHEDULE.HOW HAVE | | | YOU DETERMINED PRESSURES LOWER THAN THE | | | LOWEST FOUND ON FBC TABLE 1609.6B?IF | | | YOU ARE USING ASCE7-02, ENGINEERING IS | | | REQUIRED.YOU MAY ELIMINATE THAT COLUMN | | | FROM THE CHART IF YOU DO NOT KNOW HOW TO | | | FILL IT OUT AS YOUR ANCHORING IS | | | COMPLIANT FOR UP TO -59.6. | | | | | | ALSO SHEET 4 HAS -29.67 HIGHLIGHTED. | | | SEE FBC TABLE 1609.6B, TOO LOW FOR THIS | | | WIND ZONE. |
|