Plan Review Notes
Plan Review Notes For Permit 06040144
Permit Number 06040144
Review Stop B
Sequence Number 2
Notes
Date Text
2006-04-21 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 FROM PREVIOUS LIST
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.PLEASE KEEP THE
 NOC PROVIDED IN THE PACKAGE.
  
 2.)THE CERTIFICATE OF AUTHORIZATION
 NUMBER FOR THE ENGINEERING FIRM IS
 REQUIRED TO BE ON THE PLAN,
 FAC61G15-23.002.
  
 NOT ADDRESSED.
  
 3.)THE ENGINEER'S SEAL IS EXPIRED.IT
 IS TO STATE "LICENSE", NOT
 "CERTIFICATE", FAC61G15-23.ALSO SEE
 THE FPBE WEBSITE, WWW.FBPE.ORG.
  
 4-7.)ADDRESSED.
  
 8.)THE ENGINEER HAS SPECIFIED 110PSF
 AS THE DESIGN PRESSURE.HE HAS
 SPECIFIED METAL ROOFING PANELS WHICH
 HAVE A DESIGN PRESSURE LIMITATION OF
 -41.5PSF, ENHANCED FASTENING NOT ALLOWED
 FOR FIELD OR PERMETER ZONES ACCORDING TO
 PRODUCT LIMITATION #1 OF THE NOA.
 ADDRESS.
  
 KEEP THE EMAIL FROM MIAMIDADE IN THE
 PACKAGE.WIND DESIGN INFORMATION SHOULD
 BE A PART OF THE PROJECT SPECIFICATION,
 INCLUDING DESIGN PRESSURES FOR
 COMPONENTS AND CLADDING FBC1603.1.4.
  
 9-13.)ADDRESSED.PLEASE INCLUDE THE
 WIND DESIGN INFORMATION INCLUDED WITH
 THE RAS 137 IN THE PROJECT
 SPECIFICATION, SEE #8.
  
 THE CALCULATIONS FOR RAS137 ARE TO BE
 SIGNED, SEALED, DATED.INCLUDE ALL
 INFORMATION REQUIRED BY FAC61G15-23.002.
  
  
 14.)FLORIDA STATE OR LOCAL PRODUCT
 APPROVAL REQUIRED IN ADDITION TO THE
 NOAS SUBMITTED, FAC9B72.
 WWW.FLORIDABUILDING.ORG
  
 IF A STATE PRODUCT APPROVAL IS NOT
 AVAILABLE, PLEASE ADVISE AND A LOCAL
 PRODUCT APPROVAL WILL BE ISSUED.
  
 NOT ADDRESSED.