Plan Review Notes
Plan Review Notes For Permit 06040085
Permit Number 06040085
Review Stop P
Sequence Number 3
Notes
Date Text
2006-06-29 00:00:00DENIED;
  
 1. (THIRD REQUEST) FLOOR DRAIN IN 2ND
 FLOOR APARTMENT RIGHT SIDE IS STILL
 SHOWN ON THE FLAT DRAWING AND RISER
 DIAGRAM. PLEASE DELETE.
 2. (SECOND REQUEST) DRINKING FOUNTAINS
 ARE REQUIRED PER FBC-2006 PLUMBING SEC.
 410.1. NO BOTTLED WATER.
 3.(SECOND REQUEST) WATER HEATER DETAIL;
 SHUTOFF VALVE FORWATER HEATER IS
 REQUIREDTO BE BEFORE THE EXPANTION TANK
 FOR SERVICE.
 4.(THIRD REQUEST) H/C BATHROOM DOORIN
 SUITE "A" IS REQUIRED TO BE CATTY-CORNER
 TO THE TOILET FBC-2004 SEC. 11-4.17.3.
 5.(SECOND REQUEST)AUTOMATIC CLOTHES
 WASHERS BRANCH DRAINS TO BE 3" PER
 PLUMBING CODE SEC.406.3 WITH A CLEANOUT
 AT 48" ABOVE FINISH FLOOR.
 6.(SECOND REQUEST) PLEASE DELETE WALK IN
 COOLER FROM PAGE P-2.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695