| 2006-03-28 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- FLAT ROOF SYSTEM: A) ENGINEER TO | | | REVIEW GENERAL LIMITATION #7 AND PROVIDE | | | CALCULATIONS PER STANDARD RAS 117. | | | INFORMATION SUBMITTED DOESN'T APPLY TO | | | THIS STANDARD. | | | | | | B) ENGINEER TO REVIEW SPECIFIC PRODUCT | | | APPROVAL SUBMITTED TO SEE FASTENER TYPE | | | AND SPACING AND MAXIMUM DESIGN PRESSURES | | | ALLOWED. | | | | | | 2- SPECIFY HOW ARE CLAY TILES ATTACHED. | | | POLYFOAM, PROVIDE PRODUCT APPROVAL. | | | NAILS OR SCREWS TYPE AND NUMBER TO | | | VERIFY COMPLIANCE WITH THE UPLIFT | | | MOMENT. | | | | | | 3- OWES $205.68 FOR UPDATED VALUATION. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|