| 2006-04-07 00:00:00 | DENIED |
| | |
| | 1)A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2) PLEASE CLARIFY THE SCOPE OF WORK. |
| | VERIFY THAT OFFICES 1, 2 AND 3 ARE |
| | EXISTING AND HAVE EXISTING FOUNDATIONS. |
| | |
| | 3) SPECIFY THE CODE EDITION, |
| | CONSTRUCTION TYPE AND TYPE OF OCCUPANCY. |
| | INDICATE IF THE AREA IS FIRE |
| | SPRINKLERED. |
| | |
| | 4) SPECIFY THE WIND DESIGN DATA, SUCH AS |
| | WIND SPEED, IMPORTANCE FACTOR, ETC. SEE |
| | 2004 FBC 1603.1.4. |
| | |
| | 5) SHOW COMPLIANCE WITH 2004 |
| | FBC(EXISTING BUILDINGS) FOR LEVEL 2 |
| | ALTERATIONS. SEE SECTIONS 601 THRU 611. |
| | |
| | 6) SPECIFY INTERIOR FINISH FLAME SPREAD |
| | AND FIRE RESISTANCE. |
| | |
| | 7) FBC 1805.2 REQUIRES FOOTINGS TO HAVE |
| | A MINIMUM DEPTH OF 12". CLARIFY THAT |
| | ITEM #4 FOR NEW RAISED CONCRETE FLOOR IS |
| | POURED OVER AN EXISTING FOUNDATION. |
| | |
| | 8) SPECIFY THE FASTENING FOR THE PLYWOOD |
| | TO THE NEW 2X8 JOISTS. SEE FBC TABLE |
| | 2304.9.1. (6"OC EDGES & INTERMEDIATE AND |
| | 4"OC IN ZONE 3). |
| | |
| | 9) PROVIDE A WINDOW AND DOOR BUCK |
| | DETAIL/FRAMING DETAIL FOR WINDOW AND |
| | DOOR OPENINGS. |
| | |
| | 10) SPECIFY THE R-VALUE FOR WALL AND |
| | CEILING INSULATION. COMPLY WITH FBC |
| | CHAPTER 13. |
| | |
| | 11) SPECIFY THE ROOF COVERING AND SUBMIT |
| | FL PRODUCT APPROVALS FOR ROOFING. |
| | |
| | 12) INDICATE HOW THE ACCESSIBLE ROUTE |
| | WILL BE MAINTAINED FROM THE EXTERIOR |
| | INTO OFFICE 1 AND FROM BOTH EXTERIOR AND |
| | INTERIOR INTO OFFICE TWO WHEN THE CONC. |
| | FLOORS ARE RAISED. SEE FBC 11-4.1.6. |
| | |
| | 13) SUBMIT FL PRODUCT APPROVALS FOR THE |
| | SIMPSON CONNECTORS. |
| | |
| | 14) CITY OF WPB AMENDMENTS TO FBC |
| | 106.3.3 REQUIRES THOSE PRODUCTS WHICH |
| | ARE REGULATED BY DCA RULE 9B-72 TO BE |
| | REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL. |
| | |
| | 15) SPECIFY THE POSITIVE AND NEGATIVE |
| | WINDLOAD PRESSURES AT THE EXTERIOR |
| | OPENINGS FOR THE NEW WINDOWS AND DOORS. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |