Plan Review Notes
Plan Review Notes For Permit 06031168
Permit Number 06031168
Review Stop P
Sequence Number 1
Notes
Date Text
2006-05-31 00:00:00DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 BUILDING
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. ALL ARCHITECTURAL SHEETS: DATE
 REQUIRED ON THE SEAL WHEN THE SEAL AND
 SIGNATURE ARE AFFIXED TO THE DOCUMENTS.
 THE TITLE BLOCK MUST, AT A MINIMUM,
 CONTAIN AMONG OTHER REQUIREMENTS, (2)
 FIRM LICENSE NUMBER, (5) A SPACE FOR THE
 SIGNATURE & DATED SEAL, & (6) A SPACE
 FOR THE PRINTED NAME OF THE PERSON
 SEALING THE DOCUMENT. FAC 61G1-16.003,
 61G1.004(2)(5)(6) & FS 481.219,
 481.2055.
  
 2. ALL PLUMBING, MECHANICAL, FIRE, &
 ELECTRICAL SHEETS: ENGINEERS SHALL
 LEGIBLY INDICATE THEIR NAME, ADDRESS AND
 LICENSE NUMBER ON EACH SHEET. IF
 PRACTICING THROUGH A DULY AUTHORIZED
 ENGINEERING BUSINESS, ENGINEERS SHALL
 LEGIBLY INDICATE THEIR NAME AND LICENSE
 NUMBER, AS WELL AS, THE NAME, ADDRESS,
 AND CERTIFICATE OF AUTHORIZATION NUMBER
 OF THE ENGINEERING BUSINESS ON EACH
 SHEET. NOTE THAT THE BUSINESS NAME ON
 THE TITLE BLOCK IS DIFFERENT FROM THE
 BUSINESS REGISTERED WITH THE DBPR
 WEBSITE. (KLG/PAIGE INC.). PLEASE
 CORRECT TITLE BLOCKS THE REFLECT
 INFORMATION IN DBPR WEBSITE. (SEE
 ATTACHED SHEETS).
  
 3. ALL PME & FIRE SHEETS. NEW SEAL
 REQUIRED FOR ENGINEER OF RECORD.
 "LICENSE" SHALL APPEAR ON ALL SEALS AS
 OF 01-01-06 AS THAT IS THE END OF A 2
 YEAR GRACE PERIOD FROM THE FLORIDA BOARD
 OF PROFESSIONAL ENGINEERS. (SEE ATTACHED
 SHEET).
  
 4. SHT A7.0 ELEVATION 1 A FORWARD
 APPROACH CLEAR FLOOR SPACE IS REQUIRED
 FOR THE BREAK ROOM SINK EXTENDING A
 MAXIMUM OF 19" UNDERNEATH THE SINK.
 CABINET DOORS ARE NOT APPROVED IN THE
 CLEAR FLOOR SPACE. SECTION 11-4.24.5.
 SHOW ON THE FLOOR PLAN.
  
 5. SHT P1.0 WATER SUPPLY TO THE
 HUMIDIFIER SHALL HAVE BACKFLOW
 PROTECTION. SECTION 608.3. AN RPZV
 BACKFLOW WILL BE REQUIRED, AND BE
 INSTALLED A MAXIMUM 4' ABOVE THE FLOOR
 FOR SERVICING AND CERTIFICATION. PLEASE
 INDICATE ON PLANS. SECTION 608.13.2.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6713
 E-MAIL [email protected]
  