Plan Review Notes
Plan Review Notes For Permit 06031107
Permit Number 06031107
Review Stop B
Sequence Number 2
Notes
Date Text
2006-08-07 00:00:00BUILDING PLAN REVIEW
 PERMIT: 06031107
 ADD: 345 30TH ST
 CONT: WILLIAM J. HOLTEC
 TEL: (954)731-2998
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 /2004 EXISTING BUILDINGS- LEVEL 1
 * WEST PALM BEACH AMENDMENTS
  
 2ND REVIEW
 ACTION: DENIED
  
 1)CHALAIRE & ASSOCIATES, INC. IS MISSING
 THEIR:471.023 F.S.CERTIFICATE OF
 AUTHORIZATION.THE TITLE BLOCK FOR ANY
 SHEET BEARING THE NAME OF AN ENGINEER
 PRACTICING UNDER A FICTITIOUS NAME, A
 CORPORATION, OR A PARTNERSHIP, OFFERING
 ENGINEERING SERVICES, SHALL INCLUDE THE
 CERTIFICATE OF AUTHORIZATION NUMBER.
 ADD THE NUMBER TO EACH SHEET.THIS MAY
 BE ADDED BY HAND.
  
 2) COMPLIED.
  
 3) COMPLIED.
  
 4) COMPLIED.
  
 5) COMPLIED.
  
 6)2ND REQUEST, 1009.11 HANDRAILS.
 STAIRWAYS SHALL HAVE HANDRAILS ON EACH
 SIDE. HANDRAILS SHALL BE ADEQUATE IN
 STRENGTH AND ATTACHMENT IN ACCORDANCE
 WITH SECTION 1607.7 . HANDRAILS FOR
 RAMPS, WHERE REQUIRED BY SECTION 1010.8
  
 7) 2ND REQUEST,HANDRAIL
 1009.11.5 HANDRAIL EXTENSIONS.
 HANDRAILS SHALL RETURN TO A WALL, GUARD
 OR THE WALKING SURFACE OR SHALL BE
 CONTINUOUS TO THE HANDRAIL OF AN
 ADJACENT STAIR FLIGHT. WHERE HANDRAILS
 ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE
 HANDRAILS SHALL EXTEND HORIZONTALLY AT
 LEAST 12 INCHES (305 MM) BEYOND THE TOP
 RISER AND CONTINUE TO SLOPE FOR THE
 DEPTH OF ONE TREAD BEYOND THE BOTTOM
 RISER.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026