| Date |
Text |
| 2006-08-07 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 06031107 |
| | ADD: 345 30TH ST |
| | CONT: WILLIAM J. HOLTEC |
| | TEL: (954)731-2998 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | /2004 EXISTING BUILDINGS- LEVEL 1 |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2ND REVIEW |
| | ACTION: DENIED |
| | |
| | 1)CHALAIRE & ASSOCIATES, INC. IS MISSING |
| | THEIR:471.023 F.S.CERTIFICATE OF |
| | AUTHORIZATION.THE TITLE BLOCK FOR ANY |
| | SHEET BEARING THE NAME OF AN ENGINEER |
| | PRACTICING UNDER A FICTITIOUS NAME, A |
| | CORPORATION, OR A PARTNERSHIP, OFFERING |
| | ENGINEERING SERVICES, SHALL INCLUDE THE |
| | CERTIFICATE OF AUTHORIZATION NUMBER. |
| | ADD THE NUMBER TO EACH SHEET.THIS MAY |
| | BE ADDED BY HAND. |
| | |
| | 2) COMPLIED. |
| | |
| | 3) COMPLIED. |
| | |
| | 4) COMPLIED. |
| | |
| | 5) COMPLIED. |
| | |
| | 6)2ND REQUEST, 1009.11 HANDRAILS. |
| | STAIRWAYS SHALL HAVE HANDRAILS ON EACH |
| | SIDE. HANDRAILS SHALL BE ADEQUATE IN |
| | STRENGTH AND ATTACHMENT IN ACCORDANCE |
| | WITH SECTION 1607.7 . HANDRAILS FOR |
| | RAMPS, WHERE REQUIRED BY SECTION 1010.8 |
| | |
| | 7) 2ND REQUEST,HANDRAIL |
| | 1009.11.5 HANDRAIL EXTENSIONS. |
| | HANDRAILS SHALL RETURN TO A WALL, GUARD |
| | OR THE WALKING SURFACE OR SHALL BE |
| | CONTINUOUS TO THE HANDRAIL OF AN |
| | ADJACENT STAIR FLIGHT. WHERE HANDRAILS |
| | ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE |
| | HANDRAILS SHALL EXTEND HORIZONTALLY AT |
| | LEAST 12 INCHES (305 MM) BEYOND THE TOP |
| | RISER AND CONTINUE TO SLOPE FOR THE |
| | DEPTH OF ONE TREAD BEYOND THE BOTTOM |
| | RISER. |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |