| Plan Review Notes For Permit 06030995 |
| Permit Number |
06030995 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2006-05-10 00:00:00 | DENIED | | | | | | 1) THE PRODUCT APPROVAL SUBMITTED FOR | | | THE FLAT ROOF IS A SYSTEM FOR FOR STEEL | | | DECKS. THE BUILDING PLANS FOR THIS | | | STRUCTURE SPECIFY A CONCRETE SLAB OVER A | | | VENTED METAL DECK. RIGID INSULATION IS | | | SPECIFIED ON TOP OF THE CONCRETE DECK. | | | SUBMIT A PRODUCT APPROVAL FOR COVERING | | | AN INSULATED CONCRETE DECK. THE PRODUCT | | | APPROVAL SUBMITTED WITH THE BUILDING IS | | | JOHNS MANVILLE MODIFIED BITUMEN OVER | | | CONCRETE DECKS.(FL#644 AND NOA# | | | 03-0212.07) IF YOU SUBMIT A DIFFERENT | | | PRODUCT APPROVAL A REVISION FEE WILL BE | | | ADDED TO THE PERMIT FEE. | | | | | | 2) SPECIFY THE METHOD OF ATTACHMENT THAT | | | WILL BE USED TO INSTALL THE CLAY ROOF | | | TILES. CIRCLE THE FASTENING SYSTEM IN | | | THE PRODUCT APPROVAL. THE PRODUCT | | | APPROVAL SUBMITTED FOR THE TILE ROOF | | | WITH THE BUILDING PERMIT IS MONIER | | | LIFETILE MISSION BARREL CONCRETE ROOF | | | TILE NOA# 02-1211.07. IF YOU WISH TO | | | CHANGE TILES A REVISION FEE WILL BE | | | ADDED TO THE PERMIT FEE. | | | NOTE: MEAN ROOF HEIGHT IS 54'9". 6/12 | | | SLOPE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | | | | |
|