| 2006-05-13 00:00:00 | PAUL SCHMITZ |
| | [email protected] |
| | FBC 2004 PLUMBING CODE PLAN REVIEW |
| | FBC2004 FUEL GAS CODEPLAN REVIEW |
| | FBC 2004 CH 11, FL ACESSIBILITY CODE |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPT.1, ADMINISTRATION, 2004 EDITION |
| | |
| | UNSAT |
| | 1) SHT A-1 CODE INFORMATION: REFERE TO |
| | FBC 2004 CODES. |
| | 2) SHT A-1 INDEX OF DRAWINGS PLUMBING |
| | PLANS NOT INCLUDED IN THIS SET. |
| | 3) SHT A-9 ROOF PLAN, CH 11 STORM |
| | DRAINAGE. PROVIDE CALCULATIONS FOR |
| | PRIMARY AND SECONDARY DRAINAGE, WITH |
| | ISOMETRIC DRAWINGS, ALL PIPE SIZES. |
| | 4) OFFICE REST ROOM SEC 11-4.1.3 (11) |
| | (11) TOILET FACILITIES. IF TOILET ROOMS |
| | ARE PROVIDED, THEN EACH PUBLIC AND |
| | COMMON USE TOILET ROOM SHALL COMPLY WITH |
| | SECTION 11-4.22. OTHER TOILET ROOMS |
| | PROVIDED FOR THE USE OF OCCUPANTS OF |
| | SPECIFIC SPACES (I.E., A PRIVATE TOILET |
| | ROOM FOR THE OCCUPANT OF A PRIVATE |
| | OFFICE) SHALL BE ADAPTABLE. IF BATHING |
| | ROOMS ARE PROVIDED, THEN EACH PUBLIC AND |
| | COMMON USE BATHROOM SHALL COMPLY WITH |
| | SECTION 11-4.23. ACCESSIBLE TOILET ROOMS |
| | AND BATHING FACILITIES SHALL BE ON AN |
| | ACCESSIBLE ROUTE. |
| | 5) PLEASE SEE ANY POSSIBLE COMMENTS FROM |
| | OTHER TRADES WHICH MAY AFFECT PLUMBING |
| | PLANS. |
| | |
| | END OF COMMENTS, QUESTIONS 561-805-6692 |
| | |
| | |