| Date |
Text |
| 2006-08-13 00:00:00 | PAUL SCHMITZ |
| | [email protected] |
| | FBC 2004 PLUMBING CODE PLAN REVIEW |
| | FBC2004 FUEL GAS CODEPLAN REVIEW |
| | FBC 2004 CH 11, FL ACESSIBILITY CODE |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPT.1, ADMINISTRATION, 2004 EDITION |
| | |
| | UNSAT |
| | 1) NOTE ONE, OK |
| | |
| | 2) SHT A-2.04 NOTE TWO, OK |
| | |
| | |
| | 3)SHT A-2.04 UNSAT:NEW COMMENT |
| | DOOR SWINGS INTO TURNING SPACE. |
| | RESPONSE: SEE SHT A-301 |
| | PROVIDE ASELEVATION DETAIL OF TOILET |
| | ROOMS WITH DIMENSIONS. |
| | 11-4.22 TOILET ROOMS. |
| | 11-4.22.2 DOORS. |
| | (1)ALL DOORS TO ACCESSIBLE TOILET ROOMS |
| | SHALL COMPLY WITH SECTION 11-4.13. DOORS |
| | SHALL NOT SWING INTO THE CLEAR FLOOR |
| | SPACE REQUIRED FOR ANY FIXTURE. |
| | 11-4.22.3 CLEAR FLOOR SPACE. |
| | THE ACCESSIBLE FIXTURES AND CONTROLS |
| | REQUIRED IN SECTIONS 11-4.22.4, |
| | 11-4.22.5, 11-4.22.6 AND 11-4.22.7 SHALL |
| | BE ON AN ACCESSIBLE ROUTE. |
| | AN UNOBSTRUCTED TURNING SPACE COMPLYING |
| | WITH SECTION 11-4.2.3 SHALL BE PROVIDED |
| | WITHIN AN ACCESSIBLE TOILET ROOM. |
| | THE CLEAR FLOOR SPACE AT FIXTURES AND |
| | CONTROLS, THE ACCESSIBLE ROUTE, AND THE |
| | TURNING SPACE MAY OVERLAP. |
| | |
| | 4-A) SHTS P0.1 UNSAT: NOT ADDRESSED. |
| | PROVIDE ABBREVIATION FOR "SA" |
| | NOT TO BE INSTALLED AT TOP OF RISER |
| | NEW COMMENT. |
| | 604.9 WATER HAMMER. |
| | THE FLOW VELOCITY OF THE WATER |
| | DISTRIBUTION SYSTEM SHALL BE CONTROLLED |
| | TO REDUCE THE POSSIBILITY OF WATER |
| | HAMMER. A WATER-HAMMER ARRESTOR SHALL BE |
| | INSTALLED WHERE QUICK-CLOSING VALVES ARE |
| | UTILIZED. WATER-HAMMER ARRESTORS SHALL |
| | BE INSTALLED IN ACCORDANCE WITH THE |
| | MANUFACTURER?S SPECIFICATIONS. |
| | WATER-HAMMER ARRESTORS SHALL CONFORM TO |
| | ASSE 1010. |
| | |
| | 4-B) SHTP0.1 NEW COMMENT |
| | PLUMBING SPECIFICATIONS |
| | MATERIALS: VALVES |
| | REFERENCE TO NOTE "B" PROVIDE BALL |
| | VALVES WITH LOCKING HANDLES FOR MEDICAL |
| | GAS SYSTEMS. |
| | PLEASE REMOVE NOTE, OR EXPLAIN USE. |
| | |
| | 5) SHT P2.3 UNSAT |
| | SEE COMMENT 4-A, "SA" NOT ADDRESSED. |
| | SEC.604.9WATER HAMMER ARRESTOR |
| | REQUIRED ON I.M. |
| | END OF COMMENTS QUESTIONS 561-805-6692 |
| | |