Plan Review Notes
Plan Review Notes For Permit 06030473
Permit Number 06030473
Review Stop B
Sequence Number 1
Notes
Date Text
2006-04-04 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED
 ITEMS APPLY
  
 ____1.A NOTICE OF COMMENCEMENT MUST
 BE FILED WITH THE CLERK OF COURTS BEFORE
 A PERMIT CAN BE ISSUED, FS713.13.
  
 ____2.PROVIDE BUILDING HEIGHT.
 DESIGN PRESSURES FOR BUILDINGS OVER
 60FEET ARE REQUIRED TO BE DESIGNED USING
 ASCE7, FBC1609.1.1. DOCUMENTS PREPARED
 BY AN ENGINEER AND SUBMITTED FOR PUBLIC
 RECORD ARE TO BE SIGNED SEALED ORIGINALS
 FAC61G15-23.002.
  
 ____3.PROVIDE A COPY OF THE CONDO
 ASSOCIATION APPROVAL.
  
 ____4.COMPLETE THE ATTACHED
 INSTALLATION SCHEDULE OR PROVIDE
 REQUIRED INFORMATION IN A SIMILAR
 FORMAT.YOU MAY SHOW ANCHOR SPACING BY
 CIRCLING IT ON THE APPROPRIATE CHARTS ON
 THE PRODUCT APPROVAL.
  
 _XX_5.FLORIDA STATE OR LOCAL PRODUCT
 APPROVAL REQUIRED, FAC9B72,
 WWW.FLORIDABUILDING.ORG.
  
 THE PRODUCT APPROVAL SUBMITTED IS
 EXPIRED, FBC2001 RATHER THAN FBC2004.
  
 _XX_6.ON THE PRODUCT APPROVAL, MARK
 WHICH DETAILS APPLY TO THIS JOB.PLEASE
 USE INK RATHER THAN A HIGHLIGHTER.
  
 ____7.SHOW THE EMERGENCY MEANS OF
 ESCAPE, FBC R310.
  
 ____8.PROVIDE A FLOOR PLAN SHOWING
 WHERE THE SHUTTERS WILL BE INSTALLED AND
 PANEL SIZES WHICH CORRELATES WITH THE
 INSTALLATION SCHEDULE, ITEM 4 ABOVE.
  
 _XX_ 9.ON THE ANCHORING SCHEDULE,
 YOU HAVE INDICATED THAT THIS APPLICATION
 IS POURED CONCRETE.AREN'T THERE FILLED
 CELLS AT SOME OF THE OPENINGS?
  
 _XX_ 10.IT IS NOT CLEAR HOW YOU HAVE
 ARRIVED AT THE DESIGN PRESSURES
 DECLARED.SEE TABLE FBC1609.6B, WHICH
 HAS THE LOWEST PRESSURE AS -33, BUT YOUR
 PAPERWORK SHOWS -28.435.