Plan Review Notes
Plan Review Notes For Permit 06030341
Permit Number 06030341
Review Stop B
Sequence Number 2
Notes
Date Text
2006-05-15 00:00:001) SUBMIT AN EXISTING FLOOR PLAN OF THE
 BUILDING TO SHOW ALL NEW CHANGES OF THE
 PROPOSED LAY-OUT.
  
 2) 110.2* W. P. B. ADMINISTRATIVE CODE,
 INFORMATION THAT IS REQUIRED FOR RECORD
 KEEPING & FOR CERTIFICATE OF OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE DESIGN OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 F) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT.
  
 3) SHEET D-1 #1. A PORTION OF THE MAIN
 COUNTER WHICH IS A MINIMUM OF 36" IN
 LINGTH SHALL BE PROVIDED WITH A MAXIMUM
 HEIGHT OF 36". OR AN AUXILIARY COUNTER
 WITH A MAXIMUM HEIGHT OF 36" IN CLOSE
 PROXIMITY TO THE MAIN COUNTER SHALL BE
 PROVIDED: 11-7 (I)(II). THE DIMENTIONS
 GIVEN WILL HAVE A COUNTER HEIGHT OF
 37"AFF.
  
 4) SHEET D-2 MENTION SEE DETAIL 5/D2,
 HOWEVEER,THERE IS NO #5 DETAIL ON SHEET
 D-2. A DETAIL DRAWING FOR EACH WALL IS
 REQUIRED INDICATING TOP AND BOTTOM
 ATTATCHMENT AND ALL MATERIALS. ALSO
 INDICATE THE STUD SPACING OF EACH WALL.
 CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE
 NATURE AND EXTENT OF THE WORK PROPOSED
 AND SHOW IN DETAIL THAT THE WORK WILL
 MEET 2004 FBC. AND RELEVENT LAWS.
 FBC.SEC.106.1.1
  
 5) A SEPERATE PERMIT IS REQUIRED FOR THE
 NEW DOORS AND WINDOWS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561)805-6726
  
  
  
  
  