2006-03-09 00:00:00DENIED;
 1.AUTOMATIC CLOTHES WASHER DRAIN
 REQUIRED TO BE 3" SEE FBC-2004 PLUMBING
 SEC. 406.3. CLEANOUT AT 48" AFF.
 2.SECOND FLOOR BATH CANNOT DISCHARGE
 INTO THE VENT FOR THE AUTOMATIC CLOTHES
 WASHER, MUST HAVE ON STACK.
 3.FLOOR PLAN SHOWS TWO TOILETS IN MASTER
 BATHROOM SANITARY RISER DIAGRAMONLY
 SHOWS ONE.
 4.FIRST FLOOR SHOWER BATH VENT REQUIRED
 ON LAV TO VENT BATHROOM GROUP.
 5.PLEASE SUBMIT THE MANUFACTURE'S SPECS.
 FOR THE ICE MACHINE. (FLOOR DRAIN MAY BE
 REQUIRED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695