| 2006-08-28 00:00:00 | BUILDING REVIEW THIRD CHECKLIST: |
| | 1- ENGINEERING FIRM MUST PROVIDE THE |
| | CERTIFICAATE OF AUTHORIZATION NUMBER IN |
| | THE SOIL TEST REPORT AS REQUIRED BY SEC. |
| | 61G15-23.002 OF THE FLORIDA |
| | ADMINISTRATIVE CODE. |
| | ***REQUESTED ON PREVIOUS CHECKLIST AND |
| | NOT DONE. |
| | |
| | 2- AS REQUIRED BY DCA RULE 9B-72, |
| | PROVIDE FLORIDA OR LOCAL PRODUCT |
| | APPROVAL FOR: |
| | A) POCKET SLIDING GLASS DOORS AS SHOWN |
| | ON PLANS. INFORMATION SUBMITTED DOESN'T |
| | HAVE ANY DRAWINGS. |
| | |
| | B) ENGINEER TO CLARIFY WHY APPROVING |
| | THESE SLIDING GLASS DOORS IF THERE ARE |
| | NOT DRAWINGS SHOWING SPECIFIC SLIDING |
| | GLASS DOORS AND THE DESIGN PRESSURES |
| | THEY WERE DESIGNED FOR). |
| | |
| | 3- STORM SHUTTERS: |
| | A) STRUCTURE TO BE ATTACHED TO IS |
| | CONCRETE BLOCK NOT CONCRETE. REVISE |
| | ANCHOR SPACING AS REQUIRED. SEE |
| | INSTALLATION SCHEDULE SHOWN ON |
| | ENGINEERED DRAWINGS FOR ANCHOR SPACING |
| | ACCORDING TO THE DESIGN PRESSURES AND |
| | STRUCTURE TO BE ATTACHED TO (CONCRETE |
| | BLOCK). AND, REVISE INSTALLATION |
| | SCHEDULE AS REQUIRED. |
| | ***NOTE: THERE IS NOT SUCH THING AS |
| | SOLID CONRETE BLOCK. PROVIDE COMPLETE |
| | ENGINEERING ANALYSIS FOR SOLID CONCRETE |
| | BLOCK INSTALLATIONS. SEE SHUTTERS |
| | ENGINEERED DRAWINGS. |
| | |
| | 4- CONTRACTOR TO UPDATE LICENSE RECORDS. |
| | ACCORDING TO THE STATE RECORDS, LICENSE |
| | # CGC059256 IS FOR WELLINGTON EQUESTRIAN |
| | DEVELOPMENT. PERMIT APPLICATION SAYS NEW |
| | ENGLAND BUILDERS. NEED TO CORRECT |
| | INFORMATION TO MATCH. |
| | |
| | 5- ENERGY CALCULATIONS: |
| | A) SEE MECHANICAL PLAN REVIEWER |
| | COMMENTS AND REVISE AS REQUIRED. |
| | |
| | B) CALCULATIONS NEED TO BE DONE FOR |
| | WORST CASE SCENARIO OR MUST BE DONE FOR |
| | CORRECT HOUSING ORIENTATION. |
| | CALCULATIONS DON'T COMPLY WITH EITHER |
| | ONE. SEE SURVEY FOR CORRECT HOUSE |
| | ORIENTAION AND REVISE AS REQUIRED. |
| | |
| | C) REVISE OVERHANG LENGHT AND HEIGHT. |
| | SEE SEC. 13-601 FBC 2004 FOR CORRECT WAY |
| | OF CALCULATING OVERHANG LENGTH AND |
| | HEIGHT AND REVISE CALCULATIONS AS |
| | REQUIRED. |
| | |
| | D) PROVIDE COMPLETE ADDRESS AND OWNER |
| | INFORMATION. |
| | |
| | E) REVISE NAME OF CONTRACTOR. SEE ITEM |
| | #4 ABOVE. |
| | |
| | 6- NEED TO REVISE NOTICE OF COMMENCEMENT |
| | WITH CORRECT CONTRACTOR'S NAME. SEE ITEM |
| | #4 ABOVE. |
| | ALSO, NOC IS EXPIRED AFTER 90 DAYS IF |
| | WORK IS NOT STARTED. SEC. 713.13(2) |
| | FLORIDA STATUTES. |
| | |