Plan Review Notes
Plan Review Notes For Permit 06021123
Permit Number 06021123
Review Stop P
Sequence Number 1
Notes
Date Text
2006-03-29 00:00:00DENIED;
 1.PLANS ARE TO BE REVIEWED AND APPROVED
 BY THE DIVISION OF HOTEL AND RESTAURANTS
 BEFORE RESUB TO THE CITY.
 2.A SERVICE SINK IS REQUIRED PER
 FBC-2004 PLUMBING TABLE 403.1.
 3.FLOOR SINKS ARE REQUIRED FOR INDIRECT
 WASTES. (SODA DISPENSOR, ICE MACHINE,
 AND STEAM TABLE).
 4.FOOD PREP AREA DOES NOT HAVE A SINK
 FOR STORING OR PREPARATION OF FOOD. SO
 THE 3 COMPARTMENT SINK SHOULD DRAIN
 INDIRECTLY SEC. 802.1.1.
 5.WATER HEATER. SHOW DETAIL OF PLATFORM,
 AND LIST MATERIAL TO BE USED. SHOW PAN
 DRAIN AND LOCATION OF DISPOSAL AREA FOR
 PAN DRAIN. COMPLY WITH SEC.504.7.2.
 THERMAL EXPANSION CONTROL IS ALSO
 REQUIRED PER. SEC. 607.3
 6.PLEASE CHECK WITH RODMEY COMPO
 (ENVIRONMENT COMPLIANCE TECHNICIAN) WITH
 THE UTILITY DEPARTMENT FOR A GREASE TRAP
 WAVER. 822-2200 EXT 2272
 E-MAIL, [email protected].
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695