Plan Review Notes
Plan Review Notes For Permit 06021051
Permit Number 06021051
Review Stop B
Sequence Number 1
Notes
Date Text
2006-03-30 00:00:00 
  
 ******PROVISO*******
  
 EMERGENCY EGRESS PER R310 FBC:
 MIN. NET CLEAR OPENING OF 5 SQ.FT. ON
 GRADE FLOOR. MIN. NET CLEAR OPENING ALL
 OTHER FLOORS OF 5.7 SQ.FT. IN BOTH CASES
 THE MIN.NET CLEAR HEIGHT SHALL BE 24"
 AND THE NET CLEAR WIDTH SHALL BE 20"
  
 REPLACEMENT WINDOWS THAT MEET OR ARE
 GREATER THAN THESE REQUIREMENTS SHALL BE
 ALLOWED A MAX. 5% REDUCTION IN CLEAR
 OPENING DIMENSIONS PER 505 EXISTING FBC
  
 REPLACEMENT OF WINDOWS NEED NOT MEET
 THESE REQUIREMENTS IF THERE IS NO
 REDUCTION IN THE NET CLEAR OPENING SIZE
 BETWEEN THE EXISTING AND NEW WINDOWS