| Date |
Text |
| 2006-04-19 00:00:00 | DENIED BY BUILDING |
| | |
| | 1) SUBMIT PRODUCT APPROVALS FOR THE NEW |
| | EXTERIOR WINDOWS AND DOORS. |
| | NOTE: FL. ADMIN CODE RULE 9B-72 (IN |
| | EFFECT SINCE OCTOBER 1, 2003) REQUIRES |
| | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR |
| | SITE-SPECIFIC PRODUCT APPROVAL.THE |
| | SUBMITTAL SHOULD INCLUDE THE STATEWIDE |
| | PRODUCT APPROVAL NUMBER (FL###), |
| | AVAILABLE FROM THE DEPT OF COMMUNITY |
| | AFFAIRS PRODUCT APPROVAL WEBSITE WWW. |
| | FLORIDABUILDING.ORG/PR/PR_APP_SRCH.ASPX |
| | (IF YOU FIND THAT THE QUOTED WEB PAGE IS |
| | NO LONGER AVAILABLE, PLEASE INFORM THE |
| | PLAN REVIEWER) |
| | |
| | 2) FBC 106.3.3* (CITY AMENDMENTS) |
| | PRODUCT APPROVALS. THOSE PRODUCTS WHICH |
| | ARE REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL. |
| | |
| | 3) THE CITY OF WEST PALM BEACH IS |
| | LOCATED IN THE WIND-BORNE DEBRIS REGION. |
| | FBC 1609.1.4 REQUIRES EXTERIOR GLAZING |
| | TO BE IMPACT RESISTANT OR PROTECTED WITH |
| | IMPACT RESISTANT COVERINGS. THE USE OF |
| | REMOVABLE STORM PANELS OR PERMANENTLY |
| | AFFIXED PROTECTIVE DEVICES ON COMMERCIAL |
| | BUILDINGS REQUIRE THE APPROVAL OF THE |
| | BUILDING OFFICIAL (CALL FOR DETAILS). |
| | |
| | 4) 61G1-16.004FL. ADMIN. CODE.PLANS |
| | PREPARED BY A REGISTERED ARCHITECT SHALL |
| | INCLUDE A TITLE BLOCK WHICH MUST: |
| | - STATE THE FIRM NAME, ADDRESS AND |
| | TELEPHONE NUMBER |
| | - STATE THE FIRM LICENSE NUMBER |
| | - STATE PROJECT NAME OR IDENTIFICATION |
| | - STATE DATE PREPARED |
| | - INCLUDE AN ORIGINAL SIGNATURE AND |
| | DATED SEAL |
| | - INCLUDE THE PRINTED NAME OF THE |
| | ARCHITECT SEALING THE PLANS |
| | INCLUDE THE PRINTED NAME OF THE |
| | ARCHITECT IN THE TITLE BLOCK. |
| | |
| | 5) PROVIDE A LIFE SAFETY PLAN SHOWING |
| | THE COMMON PATH OF TRAVEL AND TRAVEL |
| | DISTANCE. SEE 2004 FBC CHAPTER 10. |
| | NOTE: BASED ON OCCUPANCY, OCCUPANT LOAD |
| | AND TRAVEL DISTANCE IT APPEARS THAT ONLY |
| | ONE EXIT IS REQUIRED. |
| | |
| | 6) SPECIFY THE TYPE OF CONSTRUCTION OF |
| | THE STRUCTURE. SEE FBC 602. |
| | |
| | 7) SPECIFY THE POSITIVE AND NEGATIVE |
| | WINDLOAD PRESSURES FOR THE NEW EXTERIOR |
| | WINDOW/DOOR OPENINGS AND THE EXISTING |
| | OPENINGS WHERE WINDOWS/DOORS ARE BEING |
| | REPLACED. SEE FBC 1603.1.4(5). |
| | |
| | 8) PROVIDE BUCK FASTENING DETAILS FOR |
| | NEW WINDOW AND DOOR OPENINGS. SEE FBC |
| | 1714.5.4.2 |
| | |
| | 9) SPECIFY THE FIRE SEPARATION DISTANCE |
| | AND SHOW COMPLIANCE WITH ALLOWABLE AREA |
| | OF OPENINGS IN NORTH WALL WHERE OPENINGS |
| | ARE BEING ADDED AND INCREASED. SEE FBC |
| | 704.8, 704.3 AND 702. |
| | |
| | 10) FBC 1013.2 EGRESS THROUGH |
| | INTERVENING SPACES. |
| | EGRESS FROM A ROOM OR SPACE SHALL NOT |
| | PASS THROUGH ADJOINING OR INTERVENING |
| | ROOMS OR AREAS, EXCEPT WHERE SUCH |
| | ADJOINING ROOMS OR AREAS ARE ACCESSORY |
| | TO THE AREA SERVED; ARE NOT A |
| | HIGH-HAZARD OCCUPANCY AND PROVIDE A |
| | DISCERNIBLE PATH OF EGRESS TRAVEL TO AN |
| | EXIT. EGRESS SHALL NOT PASS THROUGH |
| | KITCHENS, STORAGE ROOMS, CLOSETS OR |
| | SPACES USED FOR SIMILAR PURPOSES. AN |
| | EXIT ACCESS SHALL NOT PASS THROUGH A |
| | ROOM THAT CAN BE LOCKED TO PREVENT |
| | EGRESS. MEANS OF EGRESS FROM DWELLING |
| | UNITS OR SLEEPING AREAS SHALL NOT LEAD |
| | THROUGH OTHER SLEEPING AREAS, TOILET |
| | ROOMS OR BATHROOMS. |
| | |
| | 11) 1005.2 DOOR ENCROACHMENT. |
| | DOORS OPENING INTO THE PATH OF EGRESS |
| | TRAVEL SHALL NOT REDUCE THE REQUIRED |
| | WIDTH TO LESS THAN ONE-HALF DURING THE |
| | COURSE OF THE SWING. WHEN FULLY OPEN, |
| | THE DOOR SHALL NOT PROJECT MORE THAN 7 |
| | INCHES (178 MM) INTO THE REQUIRED WIDTH. |
| | SEE DOOR TO ACCESSIBLE TOLIET ROOM. |
| | |
| | 12) 11-7.2 SALES AND SERVICE COUNTERS, |
| | TELLER WINDOWS, INFORMATION COUNTERS. |
| | (2)AT TICKETING COUNTERS, TELLER |
| | STATIONS IN A BANK, REGISTRATION |
| | COUNTERS IN HOTELS AND MOTELS, BOX |
| | OFFICE TICKET COUNTERS, AND OTHER |
| | COUNTERS THAT MAY NOT HAVE A CASH |
| | REGISTER BUT AT WHICH GOODS OR SERVICES |
| | ARE SOLD OR DISTRIBUTED, EITHER: |
| | (I)A PORTION OF THE MAIN COUNTER |
| | WHICH IS A MINIMUM OF 36 INCHES (915 MM) |
| | IN LENGTH SHALL BE PROVIDED WITH A |
| | MAXIMUM HEIGHT OF 36 INCHES (915 MM); OR |
| | |
| | (II)AN AUXILIARY COUNTER WITH A |
| | MAXIMUM HEIGHT OF 36 IN (915 MM) IN |
| | CLOSE PROXIMITY TO THE MAIN COUNTER |
| | SHALL BE PROVIDED; OR |
| | (III)EQUIVALENT FACILITATION SHALL |
| | BE PROVIDED (E.G., AT A HOTEL |
| | REGISTRATION COUNTER, EQUIVALENT |
| | FACILITATION MIGHT CONSIST OF: |
| | (1)PROVISION OF A FOLDING SHELF |
| | ATTACHED TO THE MAIN COUNTER ON WHICH AN |
| | INDIVIDUAL WITH DISABILITIES CAN WRITE, |
| | AND |
| | (2)USE OF THE SPACE ON THE SIDE OF |
| | THE COUNTER OR AT THE CONCIERGE DESK, |
| | FOR HANDING MATERIALS BACK AND FORTH). |
| | ALL ACCESSIBLE SALES AND SERVICE |
| | COUNTERS SHALL BE ON AN ACCESSIBLE ROUTE |
| | COMPLYING WITH SECTION 11-4.3 . |
| | REVISE RECEPTION DESK TO COMPLY. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |