| Date |
Text |
| 2006-03-14 00:00:00 | DENIED |
| | |
| | 1) THE REQUIRED EXITS FOR THE ADJACENT |
| | OCCUPANCY MUST BE MAINTAINED DURING |
| | DEMOLITION AND CONSTRUCTION. |
| | |
| | 2)PRODUCT APPROVALS SUBMITTED |
| | WITH PERMIT APPLICATION AFTER OCTOBER 1, |
| | 2003 ARE REQUIRED TO COMPLY WITH THE |
| | FLORIDA PRODUCT APPROVAL SYSTEM. FOR |
| | INFORMATION PLEASE SEE THE STATE WEBSITE |
| | AT WWW.FLORIDABUILDING.ORG. PRODUCTS |
| | WITH STATEWIDE APPROVAL ARE REQUIRED TO |
| | BE SUBMITTED WITH A COVER SHEET THAT |
| | LISTS THE PRODUCT IDENTITY NUMBER FROM |
| | THE STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. |
| | SUBMIT TWO COPIES OF STATE PRODUCT |
| | APPROVALS FOR THE NEW EXTERIOR WINDOW. |
| | |
| | 3) THE PRINTED NAME OF THE ARCHITECT |
| | SIGNING AND SEALING THE DRAWINGS IS |
| | REQUIRED. SEE FAC 61G-16.004. |
| | |
| | 4) MANEUVERING CLEARANCES AT DOORS |
| | MINIMUM OF 18" ON PULL SIDE OF DOORS |
| | REQUIRED BY 11-4.13.6. INDICATE THIS AT |
| | DOOR #2. CLARIFY DOOR SCHEDULE NOTE 2 ON |
| | A3.0. |
| | |
| | 5) SHOW LOCATIONS OF EXIT LIGHTS. SEE |
| | FBC 1006.3. |
| | |
| | 6) SPECIFY THE WALL AND CEILING FINISH |
| | CLASSES THAT ARE ALLOWED BY CODE. SEE |
| | FBC 803. |
| | |
| | 7) PROVIDE A LIFE SAFETY PLAN SHOWING |
| | THE COMMON PATHS OF TRAVEL, ETC. TO THE |
| | EXITS. SEE FBC CHAPTER 10 MEANS OF |
| | EGRESS. |
| | |
| | 8) REVISE NOTES ON SHEET A1.0 TO COMPLY |
| | WITH 2004 FBC. SECTIONS HAVE CHANGED. |
| | |
| | 9) REVISE CONSTRUCTION TYPE TO CONCUR |
| | WITH 2004 FBC. TYPE IV UNPROTECTED |
| | EQUATES TO TYPE II B. SEE FBC CHAPTER 3. |
| | |
| | 10) THE NOTE ON A1.0 STATES THAT NO FIRE |
| | SPRINKLER SYSTEM IS REQUIRED. SPECIFY IF |
| | THE STRUCTURE IS SPRINKLERED OR |
| | UNSPRINKLERED. THE NOTES GIVE TRAVEL |
| | DISTANCES, DEAD ENDS, BUILDING AREA, |
| | ETC. BASED ON A FULLY SPRINKLERED |
| | BUILDING. |
| | |
| | 11) COMMON PATH OF TRAVEL IS NOT TO |
| | EXCEED 75' IF BUILDING IS NOT |
| | SPRINKLERED PER FBC 1013.3. |
| | |
| | 12) TRAVEL DISTANCE FOR UNSPRINKLERED |
| | BUILD IS 200' AND DEAD END CORRIDOR |
| | LENGTH IS 20'. |
| | |
| | 13) THE EGRESS CAPACITY CALCUATION ON |
| | A1.0 HAS 19 PERSONS WHERE IT SHOULD HAVE |
| | BEEN 24. PLEASE CORRECT. SEE NOTATIONS |
| | ON PLAN. |
| | |
| | 14) THE OCCUPANCY AREA MODIFICATION NOTE |
| | ON A1.0 IS INCOMPLETE. IN ADDITION TO |
| | FIRE SPRINKLERS THE ONE STORY BUILDING |
| | WITH A BUSINESS OCCUPANCY IS REQUIRED TO |
| | BE SURROUNDED AND ADJOINED BY PUBLIC |
| | WAYS OR YARDS NOT LESS THAN 60' IN WIDTH |
| | IN ORDER TO HAVE UNLIMITED AREA PER FBC |
| | 507.2 |
| | |
| | 15) A TENANT SEPARATION WALL WITH A ONE |
| | HOUR FIRE-RESISTANCE RATING IS REQUIRED |
| | BETWEEN THIS SPACE AND THE ADJACENT |
| | TENANT. SEE FBC 708.1 AND 708.3. |
| | |
| | 16) CORRECT WINDLOAD INFORMATION ON |
| | SHEET A1.0. THE WINDSPEED FOR WEST PALM |
| | BEACH IS 140 MPH. THE WINDSPEED MAP IN |
| | THE 2004 FBC IS FIGURE 1609. |
| | |
| | 17)11-4.1.6(2) DUTY TO PROVIDE |
| | AN ACCESSIBLE PATH OF TRAVEL TO ALTERED |
| | AREAS SHALL BE DEEMED DISPROPORTIONATE |
| | TO THE OVERALL ALTERATION WHEN THE COST |
| | EXCEEDS 20 % OF THE COST OF THE ALTERA- |
| | TION TO THE PRIMARY FUNCTION AREA. |
| | (A)(I) AN ACCESSIBLE ENTRANCE |
| | (II) AN ACCESSIBLE ROUTE |
| | (III) AT LEAST ONE ACCESSIBLE REST- |
| | ROOM FOR EACH SEX OR A SINGLE |
| | UNISEX RESTROOM |
| | (IIII) ACCESSIBLE TELEPHONE |
| | (IV) ELEMENTS SUCH AS PARKING, STOR- |
| | AGE OR ALARMS. |
| | SUBMIT A COST BREAKDOWN SHOWING THAT 20% |
| | OF THE CONSTRUCTION COST HAS BEEN SPENT |
| | ON ACCESSIBILITY. |
| | |
| | 18)A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |
| | |