2006-07-08 00:00:00DENIED;
 1.PAGE A-3 SECONDARY DRAIN PROTECTION IS
 REQUIRED FOR FLAT PART OF ROOF. SHOW SQ.
 FT. OF ROOF SIZE ROOF DRAINS SHOW PIPING
 AND TERMANATION. SEE FBC-2004 PLUMBING
 CHAPTER 11, TABLES 1106.2 AND 1106.3 AND
 SEC 1107.
 2.PAGE P-2 WATER RISER; SHOW EXPANTION
 TANK AS REQUIRED BY SEC 607.3. IS WATER
 HEATER ON FIRST FLOOR FOR BOTH
 APARTMENTS?
 3.SANITARY RISER DIAGRAM BACK BUILDING;
 AUTOMATIC CLOTHES WASHER DRAIN TO BE 3"
 SEE SEC. 406.3.
 4. RISER DIAGRAM SHOWS 2 EXISTING
 SANITARY SEWERS IS THIS TRUE?