| 2006-07-12 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 |
| | EXISTING BUILDING CODE |
| | FBC*CITY OF WEST PALM BEACH |
| | AMENDMENTS TO THE FBC2004 |
| | |
| | FROM PREVIOUS REVIEW: |
| | |
| | 1.)A NOTICE OF COMMENCEMENT MUST BE |
| | FILED WITH THE CLERK OF COURTS BEFORE A |
| | PERMIT CAN BE ISSUED, FS713.13. |
| | |
| | 2.)IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY.THE PLANS MUST BE STAMPED |
| | AND THE RECEIPT ATTACHED TO THE |
| | APPLICATION.561-233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 3.)PROVIDE A COPY OF THE RECORDED |
| | UNITY OF TITLE. |
| | |
| | 4.)ADDRESSED. |
| | |
| | 5.)PRODUCT APPROVALS ARE TO BE |
| | SUBMITTED BY DESIGNER OF RECORD, |
| | FBC*106.3.3.(EITHER A SHOP DRAWING |
| | STAMP OR LETTER.) |
| | |
| | THE BULLET RESISTANT WINDOW HAS A DESIGN |
| | PRESSURE LIMITATION OF +-50; S7 |
| | SPECIFIES +66.2/-70.7. |
| | |
| | CIRCLE ANCHORING METHOD FOR THE IMPACT |
| | STOREFRONT AS NOT ALL OF THEM ARE |
| | COMPLIANT FOR DESIGN PRESSURES SPECIFIED |
| | ON SHEET S7. |
| | |
| | THE ENGINEERING FOR THE ARCH ALUMINUM |
| | PREPARED BY BROMLEY COOK ENGINEERING IS |
| | TO BE SIGNED, SEALED, AND DATED.A |
| | CERTIFICATE OF AUTHORIZATION IS REQUIRED |
| | FOR BROMLEY-COOK AND THE NUMBER IS TO BE |
| | PRINTED ON EACH SEALED SHEET, |
| | FAC61G15-23.002. |
| | |
| | 6.)ADDRESSED. |
| | |
| | 7.)COMPLETE A PERMIT APPLICATION FOR |
| | THE DUMPSTER ENCLOSURE AND PROVIDE WITH |
| | THE RESUBMITTAL.SEPARATE PLANS ARE NOT |
| | NECESSARY. |
| | |
| | 8.)ADDRESSED. |
| | |
| | 9.)THE PARKING STRIPING IS TO COMPLY |
| | WITH THE CITY OF WEST PALM BEACH |
| | STANDARD, SEE ATTACHED DETAIL. |
| | |
| | PLEASE REVISE THE DETAIL IN THIS PLAN, |
| | AND ALSO REVISE THE ISSUED ENGINEERING |
| | PERMIT TO AVOID CONFUSION IN THE FIELD. |
| | |
| | 10.-19.)ADDRESSED. |
| | |
| | NEW COMMENTS: |
| | |
| | 20.)THE SURVEY SHOWS THE NEW PROPERTY |
| | LINE GOING THROUGH THE MIDDLE OF AN |
| | EXISTING BUILDING.THIS CREATES A |
| | BUILDING WHICH IS NOT CODE COMPLIANT, |
| | FBC TABLE 601.PLEASE ADDRESS OR |
| | CONTACT ME TO DISCUSS. |
| | |
| | 21.)FLORIDA STATE OR LOCAL PRODUCT |
| | APPROVALS REQUIRED IN ADDITION TO THE |
| | NOAS PROVIDED, FAC9B72.IF A STATE |
| | PRODUCT APPROVAL IS NOT AVAILABLE, |
| | PLEASE ADVISE AND A LOCAL PRODUCT |
| | APPROVAL WILL BE ISSUED. |
| | WWW.FLORIDABUILDING.ORG. |