| Date |
Text |
| 2006-05-18 00:00:00 | |
| | DENIED |
| | |
| | 61G15-23.002 SEAL, SIGNATURE AND DATE |
| | SHALL BE AFFIXED. |
| | (1) A PROFESSIONAL ENGINEER SHALL SIGN |
| | HIS NAME AND AFFIX HIS SEAL TO ALL |
| | PLANS, SPECIFICATIONS, REPORTS, FINAL |
| | BID DOCUMENTS PROVIDED TO THE OWNER OR |
| | THE OWNER?S REPRESENTATIVE, OR OTHER |
| | DOCUMENTS PREPARED OR ISSUED BY SAID |
| | REGISTRANT AND BEING FILED FOR PUBLIC |
| | RECORD. THE DATE THAT THE SIGNATURE AND |
| | SEAL IS AFFIXED AS PROVIDED HEREIN SHALL |
| | BE ENTERED ON SAID PLANS, |
| | SPECIFICATIONS, REPORTS, OR OTHER |
| | DOCUMENTS IMMEDIATELY UNDER THE |
| | SIGNATURE OF THE PROFESSIONAL ENGINEER. |
| | (2) EACH SHEET OF PLANS AND PRINTS |
| | WHICH MUST BE SEALED UNDER THE |
| | PROVISIONS OF CHAPTER 471, F.S., SHALL |
| | BE SEALED, SIGNED AND DATED BY THE |
| | PROFESSIONAL ENGINEER IN RESPONSIBLE |
| | CHARGE. ENGINEERS SHALL LEGIBLY INDICATE |
| | THEIR NAME, ADDRESS, AND LICENSE NUMBER |
| | ON EACH SHEET. IF PRACTICING THROUGH A |
| | DULY AUTHORIZED ENGINEERING BUSINESS, |
| | ENGINEERS SHALL LEGIBLY INDICATE THEIR |
| | NAME AND LICENSE |
| | NUMBER, AS WELL AS, THE NAME, ADDRESS, |
| | AND CERTIFICATE OF AUTHORIZATION NUMBER |
| | OF THE ENGINEERING BUSINESS ON EACH |
| | SHEET. |
| | |
| | 2) SEE FBC. TABLE 2304.9.1 FOR THE |
| | MINIMUM REQUIREMENTS FOR THE FASTENER |
| | SPACING FOR ROOF SHEETING. |
| | |
| | 3) NOTE: NO FASTENERS SHALL BE SPACED |
| | FARTHER THAN INDICATED ON THE NOA. |
| | ENHANCEMENT SHALL BE DONE FOR ZONES 2 |
| | AND 3 ONLY. |
| | |
| | 4) RAS117 10.4.5 ALL FRACTIONS ARE TO BE |
| | ROUNDED DOWN TO THE NEXT WHOLE NUMBER. |
| | |
| | 5) PLEASE LOOK CLOSELY AT RAS117 AND |
| | FOLLOW THE EXAMPLE WHEN DETERMINING THE |
| | CALCULATIONS FOR FASTENER SPACING. |
| | |
| | 6) SEE COMMENT #1 IN REGARDS TO |
| | SIGNATURES. PHOTOCOPIES AND INITIALS ARE |
| | NOT ACCEPTABLE |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | TEL:(561)805-6726 |