| 2006-03-17 00:00:00 | BUILDING REVIEW CHECKLIST: |
| | 1- NEED RECORDED NOTICE OF COMMENCEMENT. |
| | |
| | 2- PROVIDE BATHROOM WITH DOOR THAT |
| | ALLOWS 29" MIN. CLEAR OPENING. SECTION |
| | R322 2004 RESIDENTIAL CODE. |
| | |
| | 3- SPECIFY ATTIC ACCESS AND LOCATION. |
| | SEC. R807 2004 RESIDENTIAL CODE. |
| | |
| | 4- PROVIDE DRAINAGE PLAN AS REQUIRED BY |
| | SEC. R401.3 2004 RESIDENTIAL CODE. |
| | |
| | 5- RULE 9B-72 OF DCA REQUIRES FLORIDA OR |
| | LOCAL PRODUCT APPROVAL FOR: |
| | A) PRECAST LINTELS. |
| | B) TRUSS ANCHORS AND ALL STRUCTURAL |
| | CONNECTORS SPECIFIED IN PLANS. SEE PLANS |
| | C) ROOF SHINGLES. |
| | D) SLIDING GLASS DOORS. |
| | E) ENTRY DOOR. |
| | F) DOOR AT KITCHEN/CARPORT AREA. |
| | G) SINGLE HUNG WINDOWS. |
| | |
| | ***NOTE: |
| | DADE COUNTY NOA'S ALONE ARE NOT |
| | AUTOMATICALLY STATEWIDE FLORIDA PRODUCT |
| | APPROVALS. GO TO THE DCA FLORIDA WEBSITE |
| | WWW.FLORIDABUILDING.ORG TO DOWNLOAD |
| | APPROVED FLORIDA PRODUCT APPROVALS. |
| | OTHERWISE, MANUFACTURER TO APPLY FOR |
| | LOCAL PRODUCT APPROVALS. |
| | |
| | 6- DESIGNER OF RECORD TO REVIEW AND |
| | APPROVE IN WRITTING (OR USE STANDARD |
| | REVIEW STAMP) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS |
| | TO FBC 2004. |
| | |
| | 7- DRAWINGS WERE STAMPED FOR IMPACT FEES |
| | ON 12-07-05. PERMIT APPLICATION WAS |
| | SUBMITTED ON 2-15-06. PLANS TO BE |
| | RE-STAMPED BY PALM BEACH COUNTY TO |
| | VERIFY THAT NO ADDITIONAL FEES ARE DUE |
| | SINCE IMPACT FEES CHANGED AFTER JANUARY |
| | 13,2006. |
| | |
| | 8- OWES $710.28 FOR UPDATED VALUATION |
| | AND RADON FEES. |
| | |
| | 9- REVISE INFORMATION IN THE ENERGY |
| | CALCULATIONS: A) PERMITTING OFFICE IS |
| | CITY OF WEST PALM BEACH, NOT PALM BEACH |
| | COUNTY. |
| | B) JURISDICTION NUMBER IS 604700, NOT |
| | 601000. |
| | |
| | 10- PROVIDE 2 SIGNED AND SEALED COPIES |
| | OF THE SOIL TEST REPORT. ONLY ONE |
| | SUBMITTED. |
| | |
| | 11- STORM SHUTTERS: A) PROVIDE FLORIDA |
| | OR LOCAL PRODUCT APPROVAL FOR STORM |
| | SHUTTERS TO BE USED. |
| | B) PROVIDE KEY PLAN. |
| | C) PROVIDE COMPLETE INSTALLATION |
| | SCHEDULE. SEE ATTACHED SAMPLE, WHICH HAS |
| | ALL INFORMATION REQ'D FOR PLAN REVIEW. |
| | |
| | 12- SHEET A-2, S-1: A) UPDATE ALL |
| | INFORMATION ON EMERGENCY EGRESS WINDOWS |
| | NOTES. SEE 2004 RESIDENTIAL CODE AND |
| | COMMENTS ON PLANS. |
| | B) GENERAL NOTES: SPECIFY CURRENT |
| | FLORIDA BUILDING CODE FOR WHICH BUILDING |
| | WAS DESIGNED. "AS ADOPTED BY THE COUNTY" |
| | IS NOT AN SPECIFIC CODE. |
| | C) DETAIL F1: SHOW GRADE LEVEL TO |
| | VERIFY COMPLIANCE WITH SEC. R403.1.4 |
| | 2004 RESIDENTIAL CODE. |
| | D) FOUNDATION PLAN: SHOW DROP FROM |
| | MAIN CONCRETE SLAB TO THE CARPORT AT |
| | ENTRY DOOR AND KITCHEN DOOR. ALSO AT |
| | SLIDING GLASS DOORS. SEE PLAN. |
| | E) SPECIFY CONCRETE SLAB JOINTS OR |
| | SPECIFY SUPPORTS SPACING FOR WWM AS |
| | REQUIRED BY SEC. R506.2.4 EXCEPTION #2 |
| | OF 2004 RESIDENTIAL CODE. |
| | F) DELETE MECHANICAL NOTE IF IT |
| | DOESN'T APPLY TO THIS PROJECT. |
| | G) UPDATE REFERENCE INFORMATION FOR |
| | OPENINGS. SEE 2004 RESIDENTIAL CODE AND |
| | COMMENTS ON PLANS. |
| | |
| | 13- SHEET S-2: A) TRUSS ANCHOR SCHEDULE: |
| | REVISE TYPO. CORRECT CONNECTOR IS TAPL16 |
| | NOT TALP16. |
| | B) REVISE NUMBER OF FASTENERS |
| | SPECIFIED FORTAPL16. SEE CATALOGUE. |
| | OTHERWISE, PROVIDE COMPLETE ENGINEERING |
| | CALCULATIONS FOR TYPE AND NUMBER OF |
| | FASTENERS THAT DIFFER FROM THOSE TESTED |
| | AND PUBLISHED BY THE MANUFACTURER. SEC. |
| | 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| | C) CONNECTOR A5 IS A WOOD TO WOOD |
| | CONNECTOR. NEED TO SPECIFY WOOD TO |
| | MASONRY CONNECTOR. REVISE AS REQUIRED. |
| | D) SPECIFY WHERE DOES DETAIL F/A-6 |
| | APPLIES TO?. OR DELETE DETAILS THAT |
| | DON'T APPLY TO THIS PROJECT. |
| | E) REVISE LENGTH FOR PRECAST LINTEL |
| | #2. SEE PLANS FOR CORRECT SPAN. |
| | |
| | 14- SHEET D-1: A) DELETE WINDOW MULLION |
| | DETAIL IF IT DOESN'T APPLY. |
| | B) TYPICAL 1 STORY SECTION: OVERHANG |
| | IS SHOWN INCORRECTLY. MISSING THE TRUSS |
| | LEG THAT ALLOWS PLACEMENT OF ATTIC |
| | VENTS. REVISE DETAIL AS REQUIRED. |
| | B) SHOW GRADE LEVEL TO VERIFY |
| | COMPLIANCE WITH R403.1.4 2004 RES. CODE. |
| | C) UPDATE ALL REFERENCE STANDARDS |
| | SPECIFIED IN THEGENERAL NOTES. SEE |
| | 2004 RESIDENTIAL CODE CHAPTER 43 FOR |
| | PROPER REFERENCE STANDARDS AND EDITION |
| | THAT ARE ADOPTED BY THE CODE. |
| | |
| | 15- PLEASE RETURN REVIEWED SET AFTER |
| | CORECTIONS ARE DONE TO THE ORIGINAL |
| | DRAWINGS TO EXPEDITE REVIEW PROCESS. |
| | |