Plan Review Notes
Plan Review Notes For Permit 06020406
Permit Number 06020406
Review Stop B
Sequence Number 1
Notes
Date Text
2006-05-03 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 1.)CERTIFICATE OF AUTHORIZATION NUMBER
 FOR THE PROFESSIONAL ASSOCIATION IS
 REQUIRED, FAC61G15-23.002.
  
 2.)EACH SHEET IS TO BE SEALED OR AN
 INDEX SHEET IS REQUIRED,
 FAC61G15-23.002.YOU HAVE INCLUDED AN
 INCOMPLETE TABLE OF CONTENTS.ADDRESS.
  
 3.)THE LETTER DATED FEBRUARY 1, 2006
 FROM DAVIS ENGINEERS PA TO WEST PALM
 BEACH REFERS TO 20TH FBC RATHER THAN
 2004 FBC (TYPO).
  
 4.)PROVIDE A SITE PLAN WHICH SHOWS
 COMPLIANCE WITH FBC TABLE 602,
 FBC3103.3..A SITE PLAN WAS PROVIDED
 BUT DOES NOT INCLUDE DIMENSIONS TO THE
 PROPERTY LINE OR TO THE FUTURE SALES
 OFFICE TRAILER.
  
 5.)THE LETTER DATED FEB 1,2006
 PROVIDES A WIND DESIGN CRITERIA OF 90MPH
 WITH REMOVAL OF THE FABRIC AT 75MPH.
 THE CITY OF WEST PALM BEACH IS IN THE
 140MPH ZONE.THE ENTIRE STRUCTURE IS TO
 BE STRUCTURALLY COMPLIANT FOR THIS WIND
 ZONE, FBC1609, FBC3102.7.
  
 6.)PROVIDE WIND DESIGN INFORMATION
 FBC1603.1.4.NOTE THAT THIS PARCEL HAS
 ALREADY BEEN DETERMINED TO BE EXPOSURE C
 BY OTHER DESIGN PROFESSIONALS.
  
 7.)DECLARE AN OCCUPANCY, FBC CHAPTER
 3.
  
 8.)THE LETTER STATES THAT THE SOIL
 CONDITIONS ARE SIMILAR TO THE DORAL
 PROJECT.THE LETTER FROM THE SOILS
 ENGINEER STATES THAT THERE IS A LIMEROCK
 SUBSTRATE.THIS AREA DOES NOT HAVE A
 LIMEROCK SUBSTRATE.A SOILS REPORT IS
 AVAILABLE FOR THIS SITE.CONSULT WITH
 THE SOILS ENGINEER FOR THIS PROJECT TO
 JUSTIFY YOUR DESIGN RATHER THAN
 ENGINEERING FROM ANOTHER PROJECT.
  
 7.)ANY SUPPORTING DOCUMENTS PREPARED
 BY AN ENGINEER AND SUBMITTED FOR PUBLIC
 RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS, FAC61G15-23.002.
  
 8.)FLAME RESISTANCE IS TO BE IN
 ACCORDANCE WITH NFPA 701.THE
 CERTIFICATE PROVIDED IS DATED 2002,
 STATES THAT IT IS FILED WITH CALIFORNIA,
 AND DOES NOT REFER TO NFPA 701.IT ALSO
 STATES THAT IT COVERS MATERIALS REFERRED
 TO ON THE REVERSE SIDE, BUT THAT SIDE IS
 BLANK.PLEASE ADDRESS.
  
 9.)PROVIDE THE EXIT DOOR DIMENSION,
 FBC10.
  
 10.)SHOW THE SIDEWALK WIDTH AND THE
 SLOPE (ACCESSIBLE ROUTE),
 FBC11-4.1.2(2).NOTE THAT THE SITE PLAN
 STATES THAT THERE IS A SLOPE IN THE
 GRADE.
  
 11.)PROVIDE THE ELEVATION ON BOTH
 SIDES OF THE DOOR, FBC11-4.1.2.
  
 12.)PROVIDE DETAILS FOR THE BATHROOM;
 TURNING RADIUS, DIMENSIONS FOR THE SINK
 AND TOILETS, GRAB BARS, ETC.THE FLOOR
 PLAN DOES NOT MATCH THE ELEVATION.
  
 13.)THE FLOOR PLAN DIFFERS FROM THE
 SITE PLAN IN THE BATHROOM LOCATION. IF
 THE BATHROOM IS LOCATED TEN FEET AWAY AS
 SHOWN, PROVIDE INFORMATION IN REGARDS TO
 THE ACCESSIBLE ROUTE.A RAMP IS SHOWN
 ON AN ELEVATION, WHAT IS THIS FOR?
  
 14.)INFORMATIONAL ONLY; NEW COMMENTS
 ARE LIKELY UPON RESUBMITTAL DUE TO THE
 LACK OF COMPLETE INFORMATION.