| Date |
Text |
| 2006-08-18 00:00:00 | DENIED |
| | |
| | |
| | 1.713.13(2) F.S.THE NOTICE OF |
| | COMMENCEMENT MUST BE RE-RECORDED BECAUSE |
| | THE DESCRIBED IMPROVEMENT OR |
| | CONSTRUCTION DID NOT COMMENCE WITHIN 90 |
| | DAYS OF RECORDING. |
| | |
| | 3.ADJUST PERMIT VALUE TO REFLECT ALL |
| | MATERIALS AND LABOR AND PAY ADDITIONAL |
| | PERMIT FEES. |
| | |
| | 4.SIGN OWNER/AGENT ON ENERGY CALCS PER |
| | 2004 FBC. |
| | |
| | 5.SUBMIT TWO COMPLETE SETS OF PRODUCT |
| | APPROVALS FOR THE FOLLOWING, INSWING |
| | DOOR, STRAPS AND TIE-DOWNS. |
| | |
| | 6.JELD-WEN DOOR AND STRAPS AND |
| | TIE-DOWNS MISSING THE FOLLOWING STATE |
| | PRODUCT APPROVAL,POMA SHUTTER ON FILE |
| | HERE OK. |
| | |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A STATE PRODUCT APPROVAL |
| | SHEETS THAT LISTS THE PRODUCT IDENTITY |
| | NUMBER FROM THE STATE. IF THE PRODUCT |
| | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT |
| | AN APPLICATION FOR LOCAL PRODUCT |
| | APPROVAL OR SITE SPECIFIC FORM PER RULE |
| | 9B-72. SEE ATTACHMENT. |
| | WWW.FLORIDABUILDING.ORG |
| | |
| | 7.THOSE PRODUCT APPROVALS WHICH ARE |
| | REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL.WPB |
| | AMENDMENT TO FBC 106.3.3.PRODUCT |
| | APPROVALS NOT LISTED ON LETTER. |
| | |
| | 9.A DESIGN PROFESSIONAL OR AN OWNER |
| | MUST ELECT ONE OR A COMBINATION OF |
| | LEVELS OF ALTERATION PURSUANT TO |
| | SECTIONS 303, 304 AND 305 OF THIS CODE. |
| | SHOW HOW PLANS WILL COMPLY WITH THE |
| | SECTION(S) SELECTED.2004 FBC EXISTING |
| | BUILDING 301.5 |
| | |
| | |
| | A.PROTECTION AGAINST DECAYR319 |
| | 2.ALL WOOD FRAMING MEMBERS THAT |
| | REST ON CONCRETE OR MASONRY EXTERIOR |
| | FOUNDATION WALLS AND ARE LESS THAN 8 |
| | INCHES FROM THE EXPOSED GROUND. |
| | 3.SILLS AND SLEEPERS ON A CONCRETE |
| | OR MASONRY SLAB THAT IS IN DIRECT |
| | CONTACT WITH THE GROUND UNLESS SEPARATED |
| | FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE |
| | BARRIER. |
| | 5.WOOD SIDING, SHEATHING AND WALL |
| | FRAMING ON THE EXTERIOR OF A BUILDING |
| | HAVING A CLEARANCE OF LESS THAN 6 INCHES |
| | FROM THE GROUND. |
| | 6.WOOD STRUCTURAL MEMBERS |
| | SUPPORTING MOISTURE-PERMEABLE FLOORS OR |
| | ROOFS THAT ARE EXPOSED TO THE WEATHER, |
| | SUCH AS CONCRETE OR MASONRY SLABS, |
| | UNLESS SEPARATED FROM SUCH FLOORS OR |
| | ROOFS BY AN IMPERVIOUS MOISTURE BARRIER. |
| | |
| | |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. SUBMIT ONE COPY OF |
| | OLD PAGES FOR REFERENCE. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET |
| | OR SPECIFICATION PAGE WHERE THE CHANGES |
| | CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | |
| | ART LANGE |
| | CONSTRUCTION SERVICES DEPARTMENT |
| | BUILDING PLANS EXAMINER |
| | 561-805-6672 |