| 2007-05-11 08:45:51 | REVISION AS BUILT ISOMETRIC SANITARY RISER DIAGRAM. | | | | | | ****************PROVISO***************** | | | FBC-2004 PLUMBING | | | (A) 802.4 STANDPIPES. (WASHING MACHINE) | | | STANDPIPES SHALL BE INDIVIDUALLY TRAPPED. STANDPIPES | | | SHALL | | | EXTEND A MINIMUM OF 18 INCHES (457MM) | | | AND A MAXIMUM OF 42 INCHES (1066MM) | | | ABOVE THE TRAP WEIR. ACCESS SHALL BE | | | PROVIDED TO ALL STANDPIPES AND DRAINS | | | FOR RODDING | | | | | | (B) 708.9 ACCESS. ACCESS SHALL BE | | | PROVIDED TO ALL CLEANOUTS. | | | NOTE: CLEANOUT FOR WASHING MACHINE TO BE AT 4' A.F.F. |
|