| Plan Review Notes For Permit 06020160 |
| Permit Number |
06020160 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2006-03-23 00:00:00 | CAREFREE THEATRE | | | 2000 SOUTH DIXIE HIGHWAY | | | | | | CONTRACTOR:SEALTITE ROOFING | | | | | | CONTACT:DERMIT BEGLEY 631.258.0846 | | | | | | 1)STRUCTURAL REPAIR/ALTERATIONS MUST | | | CONFORM TO THE FBC EXISTING BUILDINGS, | | | SECTION 407.3.1/607.3-REPAIR/LEVEL 2 | | | ALTERATIONS CONSECUTIVELY. | | | | | | | | | BUILDING PLAN REVIEW/REVISION #1:FAILED | | | | | | 1)REQUIRE ADDITIONAL DETAILS FOR THE | | | REINFORCING DOWEL EMBEDMENT LENGTH AND | | | TYPE OF EPOXY TO BE UTILIZED. | | | | | | 2)SPECIFY GRADE AND VERTICAL LAP SPLICES | | | OF THE REINFORCING STEEL.FBC2101.3 | | | | | | 3)INDICATE TYPE AND STRENGTH OF GROUT TO | | | BE PLACED IN CMU'S. | | | | | | 4)INDICATE CMU MORTAR TYPE. | | | | | | 5)FLOOR PLAN OF RETAIL SECTION | | | INDICATING LOCATION OF REPAIR. | | | | | | 6)REQUIRE EXTERIOR DOOR PRODUCT | | | APPROVALS AT NEW OPENING IN WALL. | | | | | | 7)SPECIFY EXTERIOR WALL COVERING.FBC | | | 1405.2. |
|